Electrical Engineering Interview Questions
Questions Answers Views Company eMail

in Telecom DC system-why positive +ve is made earthed.and - ve is fed to load.

2078

what is servo motor and how it works?

Godrej,

1699

WHY DG are rated in KVA or MVA ???., but ALL power plants are rated in KW or MW.,,?

Coastal Energen,

3 11073

when we gave dc supply to 220v dc motor its rpm is 1200. then we gave 180v. how many rpm of its motor. gave answer with calculation at my ID.... ravizak@ymail.com

Godrej,

1749

Why is it preferred to use a wattmeter(s) to measure power in three phase systems rather than using a combination of other instruments e.g. voltmeters, ammeters etc?

2 5382

in power station what is the electrical circuit length of spacing between power transformer and lightning arrestors,for the voltage system of 230kv,110kv,33kv,22kv,11kv?

1 3014

HOW MANY POLES ARE THERE IN 3 SLOTS PER POLE PER PHASE MOTOR

2 9101

where is used dc volage transformer,and what is highest capacity of transformer

2 4033

can you use 400 volt 3 phase and neutral and earth equipment on 440 3 phase and earth supply safely and if so how?

Maersk,

2 6623

iam working as a electrical engineer. i want to know about any license or certificates regarding my field. for my carrier and ti improve the knoweledge.,,, how we get that..and what procedures......... pls help me

1 3405

how to testing the AC 3 phase motor? and what is the test procedure & kits required for testing?

3 6588

is it ok to switch lights from a mcb instead of switches

5 5525

what is the working principle of contactor and conditions of normal open and normal close on it?

EEE,

3 27993

if any house we instaled a 1.5 ton ac and its phase cable of wiring is installed but netrual cable of wiring not instaed. my question is that is neutual of house(for other wiring is capable for ac load or a sepeart neutrual wiring required

1902

1 no. 22 kV feeder is taken from state electricity board. 350 MVA is the S.C. MVA. now i am feeding this feeder to HT Panel having 2 outgoings which further supply to 2 Transformers. Can you please suggest me the type & rating of cables are 3 of these cables same? or they are different? please help...............

TCE,

2 5389


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Why r u using pf panel. what the uses

1405


How does cost of generation from hydropower plant compare with other sources of electricity?

558


Yazaki india pvt ltd interview questions qurey related

451


I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1195


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1504






how to calculate regulation constants for over head lines? and what are the regulation constant for raccoon conductor at different voltage level and different P.F?

1353


Discuss about gear cutting machines.

697


how can we design robots

1380


State kirchoff voltage law?

607


is it possible to say motor horsepower number without seeing name plate(when name plate damaged)

3980


For the requirement of a furnace of temperature range up to 1200 oC using silicon carbide rods, What is the required rate of transformer needed (please do it with all details)?

1452


WILL SCHNEIDER MAKE ACB(MASTERPACT)TRIP ON REVERSE POWER?

1719


WTA used cb?

1359


Why the power generated in dams is complex power? Why the generators in dams cannot produce Real power directly (i.e power which has zero reactive part)?

1256


I have a relay contact rated at 220v dc which is supplied with a 24vdc from the panel,for it to trip the dampers(24vdc).What if the application of the relay changes so that it should work at its rated 220vdc then will it work at 24vdc supply given or any other consideration needs to be taken .....

1586