when we gave dc supply to 220v dc motor its rpm is 1200. then we gave 180v. how many rpm of its motor. gave answer with calculation at my ID.... ravizak@ymail.com
1827Why is it preferred to use a wattmeter(s) to measure power in three phase systems rather than using a combination of other instruments e.g. voltmeters, ammeters etc?
2 5479in power station what is the electrical circuit length of spacing between power transformer and lightning arrestors,for the voltage system of 230kv,110kv,33kv,22kv,11kv?
1 3099can you use 400 volt 3 phase and neutral and earth equipment on 440 3 phase and earth supply safely and if so how?
2 6781iam working as a electrical engineer. i want to know about any license or certificates regarding my field. for my carrier and ti improve the knoweledge.,,, how we get that..and what procedures......... pls help me
1 3485how to testing the AC 3 phase motor? and what is the test procedure & kits required for testing?
3 6752what is the working principle of contactor and conditions of normal open and normal close on it?
EEE,
3 28187if any house we instaled a 1.5 ton ac and its phase cable of wiring is installed but netrual cable of wiring not instaed. my question is that is neutual of house(for other wiring is capable for ac load or a sepeart neutrual wiring required
19581 no. 22 kV feeder is taken from state electricity board. 350 MVA is the S.C. MVA. now i am feeding this feeder to HT Panel having 2 outgoings which further supply to 2 Transformers. Can you please suggest me the type & rating of cables are 3 of these cables same? or they are different? please help...............
TCE,
2 5541Post New Electrical Engineering Questions
For a spring controlled governer the relation F = ar+b (F is the controlling force, r is the radius of rotation a and b are constants), indicates that the governer is
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
Can anyone tell me some hints about what type of questions are asked by the interviewer by an Electronics engineer when company is installing an IPP and wants a team of engineers?
what is the difference between an alternator and a synchronous motor
how to interlock 3 nos MCCBs using under voltage coil. please provide me circuit diagram?
what size steel armoured cable is required to support 1500kva capacity. would 70mm squared be enough or would I need 90 or 120mm squared 3c plus earth
what is the vvvf in the dumbwaiter?? or lift. what is the actual process?/
What is the formulae of Megger value for a A.C.Motor
Transmission voltage is kept 11KV,33KV,66KV,132KV,220KV due to form factor. What happen to 400KV and 765KV transmission voltage?
what is ps impedance test
why voltage form factor of PT are increase , when it is ecpected heigher spikes in system. how it is calculated.
what does a k rating in a transformer means?
what is the best transformer oil breakdown voltage?
Currently what is the highest capacity (MVA) of SPPg generator available in the market?
what is class of SPD and dittels of all class ?