if we use a normal natural thundering; than approx how much amount of electricity we generate?
1 27501.what is use of isolation transformer. 2.Differance between KWH,KVAH,KVARH,KVA. 3.Main use of the CT and PT.
1 9362what is the meaning of harmonic in AC waves and when which are prduce and what is the effects on line and give any other information about harmonics
1 4716A 3 phase motor operating off 415V system is developing 20Kw at an efficiency of 0.77 and power factor of 0.73. determine:- a)the line current. b)the phase current if winding are delta connected. c)the phase voltage if winding are star connected.
1 3070Whether capacitor loads can be connected for testing a diesel engine at its full load capacity? Is there any limitation of capacotir load? Which is the best load for testing DG sets?
2 4496how can we save enegry by using VFD for Resiprocating Air compressor which is having more unloading running hours
MRF,
2295Post New Electrical Engineering Questions
What is the most important precaution in any experiment with d.c. Shunt motor?
what is the eight bit unit?
How is the gain affected by the introduction of feedback in a control system.
Explain the advantages and disadvantages of hydropower plant?
What is the test block protection relay if any body know plz explained
How can we connect additional batteries to three phase ups? What are parameters we have to check when connecting?
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
Basic motor transformer generator
How much current will a 5 HP delta connected motor at no load will take?Is tat need a starter
What is inductance?
What is a differential amplifier?
What is force on parallel conductors ?
Why we are using Isolation Power Transformer inplace of commercial power transformer? What's the difference between them?
what is feed back and what are feed back amplifiers?
how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.