Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Civil Engineering Interview Questions
Questions Answers Views Company eMail

show answer/ calculate-1-2-4 ratio-concrete -cement-sand- metal-water - please brief calculation

RK Company,

2121

how to calculate the crushing strength of cement concrete paver blocks 100x100x60 mm thich.

SMA Consulting,

1979

115mm thickness brick work how to required mortar

J A Brothers,

2015

Isolated square footing quantity calculations

2 4541

how to prepare the bar bending schedule for a given rcc material?It will be more helpful if you explain me with an example?

1 3337

what is tension & compression of steel bending.

L&T,

2272

what formula used to find the length of triangle ring in column?

Hitech,

1 5390

What is the quantity of cement used for stone pitching work of 100sqm 225mm thick and cement mortar of 1:6? And how?

5134

as we take 30% of whole brick work masonry ,so how much % we take in block masonry?

azan,

1 2904

in block masonry l=10',b=0.5',H=10',Calculate cement ,sand and no.Of blocks?

azan,

1946

What is Current Shuttering rate (labour + materials) for Columns, Beam & Slab on Item rate basis ?

Atul, AVR, Pioneer,

3 44911

For 1 cu m of concrete required 1.54 Cu m times dry volume. Pl give clarification of 1.54 factor

RASA, Unity Infraprojects,

1 3979

If the first roof slab is not deshuttering in this time shall I start column raising work in second roof is it correct or not

Al Fara, Unity Infraprojects,

2 4202

how much M-25 steel reinforcement per cubic meter in commercial building as per IS code

Shyam Indus Power,

2 3915

For 1cu.m how many bricks required practically

6 7804


Post New Civil Engineering Questions

Un-Answered Questions { Civil Engineering }

Define What is made from large rocks, which protects the base of cliffs?

1040


For fine aggregate which is most suitable River sand or crusher sand & why ?

1751


I want to know the relevant IS codes of practice which deals with different testings of cement-sand mortar (nominal mix)that is being normally used for brick work or plaster work in the construction work.

2041


why is M30 grade Concrete use for Foothing & Column M50

3438


Hi I had missed my mark list (first year-apr2003)how i search in my old mark details in internet and which web site? pl inform me in full details..

1916


will fix foundation bolts at site with out template is there any procedure?

2585


In a beam,stirrups are placed closely at ends than at centre due to shear.similarly where would ties be closer to each other-at center or at ends in a column and slab.

3276


how to decide the mortar ratio 1:4,1:6 in masonry? same in plaster 1:3 and 1:4? which code or any document reference taken to define proportion?

2090


Design an underground tank of internal dimensions 6m x 3m x 3m. The soil surrounding the tank always remains dry. The tank shall be provided with a roof slab. The soil weighs 16000 N/m3 having an angle of repose of 30.

2076


Can any body help me out by telling hoe swelling pressure test of soil is carried out ? some body told me the procedure & formula (change in length /116.3*100%) but still i am confused ? pls help.

1913


Define What is a kip?

1136


Define relative co-ordinates?

1079


Thumb rule for steel qty for 1m2 in kg/m2 column slab footing beam

5573


Caching, Multithreading and RAMBUS are 3 methods for resolving the Bottleneck problem. Please give an explanation for each one (how are they resolve the problem?)

2220


what will be the cost of thickness of 125mmor rcc measurement of 52x33.75 feet

1556