Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

what is the formulae to find the thermocouple output to temperature

5 8713

what is the difference between SMART and tipical transmeter ?

Sirte Oil Company,

3 7032

How can we cheak the ENCODER ?

1 4866

What is the use of +/- 20ma in analog measurement,and which instrument gives +/-20ma output

1 3631

In s7-200 we use HMI TD-200C , what that C stands for........ plz reply

2 4625

can i use capillary type dp transmitter converted to capillary type pressure transmitter. if i removed one side capillary tube its work correctly?

1 4977

What is the use of keyphasor in turbine.

Hindustan Zinc, R&D,

7 35427

i have a dp tx range is 5000mmwc. in which calibration i use in a open tank.1.5*3.5*2.5 mtr.for level msmnt. what is the calculation.

Bajaj Hindusthan,

2 6503

capillary type tranmitter using remote seals and capillary tubes filled with liquid of known of known density so if you wanna callibrate it just close block valve just before capilary @ high side & connect druck apply it's calibrated range pressure as normal calibration ensure low side block valve must be closed & if you asking commissioning so this is not a DP type pressure tx so simple if you wanna put in servie this tx just open high side block valve & than low side block same way i do it but still transmitter showing -13 ma.just tell me what i want to do ?

Gasco,

1 4942

hye SAM acn u send your e mail id, so that i can solve my query through e mail?

2246

how to calculate temp.prapotional to mv in thermocoulpe.

Electronics, KNPC,

2 6863

Can we measure pressure using differential pressure transmitter? If yes then how?

Reliance,

5 10437

why are set -10vdc in bently neveda vibration system.

4 7693

What is the PLC configuration in Cement industry?

IMCO, Maha Cement,

3809

Can anyone send most commonley asked Instrumentation questions and answers in cement industry please?

1992


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

Please send me the sample question of Instrumentation of hpcl/iocl exam. my mail id hihi_kiholo@rediffmail.com

3207


it is possible to check the fail safe condition in pressure transmitter. if possible how?

1409


i have been asked by QAFCO to appear for interview for thy post of Instrument Designer(INTOOLS)..i m engineering graduate with 5 years exp. in design engineering.Will this job profile suit me??i need all ur help n suggestions for thy same?

2216


components of control circuit belongs to control valve

1657


What is the calibration procedure of Drum level transmitter if range is 0 to -400 mmh2o in lab?

2107


how do i tune dearator pr control valve using PID. we set the set point is 0.6kg/cm2 now i want 0.5 to 0.7kg/cm2 limits so what should i give p,i,d values. then pls explain how do set pid values for control valve tuning?

1896


How to Calibrate Level Troll in field

1401


If i have 4 Allen Bradely make RS logix 5000 PLC and for viewing that we are using 4 RS view SCADA for 4 different packages. Now, I will want to view two packages on only one SCADA. Then how i will do it?

2381


can any one explain in which term we are flow flow is it volumetric r is it mass? and y

1930


detail of mass flow meter pricipal

2299


What are advantages and disadvantage of the ac supply load cell?

1052


please any body have most important data for study for saudi aramco test of instrument QC thanks email shahnaveedullah@gmail.com

1675


Which type of pressure can be measured by these elements?

1138


How to do gas analysers calibration in AUTO and Manually by using zero and span gas?

2343


What is the difference between conductive lined pipe and conductive unlined pipe? Why do we see that?

3188