Instrumentation Interview Questions
Questions Answers Views Company eMail

what is the formulae to find the thermocouple output to temperature

5 6986

what is the difference between SMART and tipical transmeter ?

Sirte Oil Company,

3 5588

How can we cheak the ENCODER ?

1 4172

What is the use of +/- 20ma in analog measurement,and which instrument gives +/-20ma output

1 2956

In s7-200 we use HMI TD-200C , what that C stands for........ plz reply

2 3737

can i use capillary type dp transmitter converted to capillary type pressure transmitter. if i removed one side capillary tube its work correctly?

1 4342

What is the use of keyphasor in turbine.

Hindustan Zinc, R&D,

7 32720

i have a dp tx range is 5000mmwc. in which calibration i use in a open tank.1.5*3.5*2.5 mtr.for level msmnt. what is the calculation.

Bajaj Hindusthan,

2 5548

capillary type tranmitter using remote seals and capillary tubes filled with liquid of known of known density so if you wanna callibrate it just close block valve just before capilary @ high side & connect druck apply it's calibrated range pressure as normal calibration ensure low side block valve must be closed & if you asking commissioning so this is not a DP type pressure tx so simple if you wanna put in servie this tx just open high side block valve & than low side block same way i do it but still transmitter showing -13 ma.just tell me what i want to do ?

Gasco,

1 4193

hye SAM acn u send your e mail id, so that i can solve my query through e mail?

1805

how to calculate temp.prapotional to mv in thermocoulpe.

Electronics, KNPC,

2 5787

Can we measure pressure using differential pressure transmitter? If yes then how?

Reliance,

5 8395

why are set -10vdc in bently neveda vibration system.

4 6175

What is the PLC configuration in Cement industry?

IMCO, Maha Cement,

3258

Can anyone send most commonley asked Instrumentation questions and answers in cement industry please?

1536


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

Draw block digram for well head from well to shipping pump?

1733


whats the abbreviation of IOP? is it instrument of power or input open problem?

658


Working principle of magnetic flow meter ......and calibration procedure of e+h magnetic flowmeter...

1895


Why do you want to work here

1812


i have steam drum height 1000mm. and i want to placed the transmitter below the tap.how i calculate.

1496






what deference between panel earth and systemearth

1763


Which type of diagphram use in costic line,DM water line,natural gas line,oil line?

3475


Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.

1779


Q-Explain the different load conditions that will produced different offset which may or may not be acceptable to thhe control function

1731


What is the exact differences between HART,FOUNDATION FIELDBUS,PROFIBUS?

3001


What is the use of gauge?

681


Derive capacitance to 4-20ma conversion formula / relation in capacitance type pressure sensor?

1761


If we increase only P what will be controller action ?

1620


how to calibrate electro pneumatic positioner 8013 mil controls ltd ?gsr

7439


what happen if i increase height of displacer type LT.accuracy or sensitivity are affected.why?

2063