Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


coarse sand has a fineness modulus
in range of

Answers were Sorted based on User's Feedback



coarse sand has a fineness modulus in range of..

Answer / narendra

coarse sand has a fineness modulus of 2.9-3.2 while medium sand range is 2.6-2.9 and fine sand is 2.2-2.6

Is This Answer Correct ?    11 Yes 2 No

coarse sand has a fineness modulus in range of..

Answer / shahnawaz khan

course- 4.75mm to 2.0mm
medium- 2.0mm to 425 micron sieve
fine- 425 micron to 75 micron sieve

Is This Answer Correct ?    0 Yes 1 No

Post New Answer

More Civil Engineering Interview Questions

how much M-25 steel reinforcement per cubic meter in commercial building as per IS code

2 Answers   Shyam Indus Power,


the moisture content of the soil below which the soil volume becomes constant ie called liquid limit plastic limlt shrinkage limit none

1 Answers  


Is there any difference in IS 456 and IRC 15? 

1 Answers  


if in column reinforcement lower dia connect to higher dia then from wher we want to start higher dia steel

0 Answers  


Why are the bolts that hold steel rails together in oval holes?

0 Answers  


WHAT DO YOU MEAN BY MIX DESIGN OF CONCRETE?NAME THE VARIOUS METHODS OF CONCRETE MIX DESIGN.EXPLAIN I.S.METHOD OF MIX DESIGN

0 Answers  


rate analysis hiring of generator 62.5 KVA

0 Answers  


Define What glue is least sticky?

0 Answers  


What is is code for use TOR

3 Answers   L&T,


material calculations for I st coatplastering 16mm CM (1:5),second coat CM(1;3)4mm thick,pcc(1:4:8),RCC M20,lime stone masonry CM(1:6)

1 Answers  


What is the Requirements of indoor & outdoor Substation Construction? What is the main Safty Requirements for SubStation Construction?

1 Answers  


what is meant by structural design?

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)