plz drive the formula d2/162.162 for the calculation of weight of steel bars????
Answers were Sorted based on User's Feedback
Answer / maninderdeep singh
We know the formula D2/162 which is being used for
calculate unit weight of reinforcement per meter.
Here I am willing to explain how it has been arrived D2/162
(Note: D unit is in MM)
Weight of bar per meter = Area of steel bar X Density of
steel x Length of bar
= (3.14 x D2/4) x 7850 kg/m3 x 1 m
= D2 X 6162.25/(1000x1000)
= D2 X (0.006162)
= D2 X 1/(0.006162)-1
= (D2/162.28)
The actual value is D2/162.28
Kindly note that this function is only applicable for
circular shape steel which density is 7850kg/m3
Is This Answer Correct ? | 69 Yes | 10 No |
Answer / azam
this is the co effieent factor after express of 7850 kg/m3.
Is This Answer Correct ? | 11 Yes | 0 No |
Answer / santosh singh
density of steel - 7850 kg/m3
weight of steel per meter= 3.142/4 x (d/1000)2 x 7850
solving thiswt / meter of steel rod = d2/162.19
Is This Answer Correct ? | 9 Yes | 1 No |
Answer / venkatesh
this is the co effieent factor for steel weight
calcullaction
Is This Answer Correct ? | 7 Yes | 2 No |
what is meant by Stagging?
For the calculation of bearing pressure below the footing, to know whether it is below the safe bearing pressure of the soil, the unit of RCC below ground level to be taken is 25 KN/m3 or (25-15)KN/m3, where 25 is the unit weight of RCC and 15 is the unit weight of soil and whether the weight of backfilling to be taken?
Why are pull-out tests performed for soil nails?
Concrete how muvh strenght gain 7days,14day,s,21day's,28day's&56day's after curing
what is the effect of earthquake on rcc columns & foundations?
brick size-230x110x75, how many no of bricks cover 1cubic meter.
What is the unit weight of cement?
Standard weighs for different grades of concrete?
How to layout the site plot ? Method with explation
what is civil engineering?
2 Answers CPWD, drda, Jal Nigam, NHPC, Uttar Pradesh Jal Nigam,
If your drg told used 600 dia hume pipe for culvert but due to market problem available 300 dia hume pipe,den how much humepipe you provide(300 dia) instead of 600 dia?
What is the cost of Brickwall ( 4")(1:4) thick wall total Area 245 sqft with plaster(1:6). With all materials including.