Need to design filter...Length and diamter of shell
Answer / yash patel
Now i have posted all the required details .
Need to Design Filter .Where Polypropylene wound cartridge
to be fitted. Would you please help me carrying out the
design part. Especially length and Diameter of Shell.Please
help me out in performing calculations.Since i know now all
the basics .but one or the other hand its not getting solved
due to lack of knowledge.
If you don’t mind ,would you please solve it for my sake
once.
Type: Multiple Elements
Material Removed : PVC Particles
Design Data
Fluid Handled: VCM Vapor + Water Vapor
Flow M3/Hr Normal :318
Maximum:365
Density :2.67 kg/m3
Viscosity : 0.01
Operating Temp:54` C
Operating Pressure: 0.2 kg/cm2
Design Temp :170 `C
Design Pressure: 2.8 kg/cm2
Maximum Allowable Pressure Drop :0.01 kg/cm2
Desired Particle Retention, Filter Mesh to be Used:10
micron
MOC Shell: Carbon Steel
Filter Element: 304 SS
Inlet/Outlet Connections: 6 inch Flange
Vent/Drain Size :1 inch /3 inch
Line size : 6 inch
Clean Pressure drop across the filter: 0.006kg/cm2
Dirty Pressure drop across the filter: 0.02kg/cm2
Size of Filter Element:
ID : 30 mm
OD : 62 mm
Length : 750 mm
Where PP wound filter to be Fitted.
Please help me out.
Regards
Yash Patel
http://yashpatel.co.nr/
Is This Answer Correct ? | 1 Yes | 0 No |
Name some common problems associated with dilute phase pneumatic conveying?
MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)
what is meaning of pid how it is useing controlers
can hydrogen vent to atm openly from cylinder
Explain how do you design a vapor-liquid separator or a flash drum?
what is first order of reaction?
what is difference between B.Tech. and B.E. in chemical engineering
Is it ever advantageous to use shells in series even though it may not be necessary?
solution =2oolitre ,solute =Polyelectrolyte,Solution=water ,we have to prepare 1% solution.how much solute And Solvent?
0 Answers Nixie Engineers Pvt Ltd,
What are some common causes of control valve noise?
The power required for size reduction in crushing is???
Question 61 – A biochemical trolley of mass 15 kg is towing a trailer of mass 5 kg along a straight horizontal pathway. The trailer and the trolley are connected by a light inextensible tow-bar. The engine of the trolley exerts a driving force of magnitude 100 N. The trailer and the trolley experience resistances of magnitude 10 N and 30 N respectively. (a) Form 2 equations with unknowns T and a, that represents the equilibrium for the 2 systems of the trolley and trailer. (b) Solve the simultaneous equations from the 2 equations that are obtained in part (a) of this question. T is the tension of the tow-bar and a is the acceleration.