Answer / habib
Because Feed Water Tank is placed at height. Why feed water
tank is placed at height? For Feed water pump- NPSH.
Is This Answer Correct ? | 2 Yes | 1 No |
Answer / shailendra
To provide the net possitive suction head for boiler feed pump
And this npsh is prevent the bfp from cavitation..
Is This Answer Correct ? | 0 Yes | 0 No |
how to calculate a id fan capacity and sutable motor in kw's.i have a fan impeller dia is 1050mm, width is 105mm in impeller inside to inside,and impeller section cone gap is 450mm, impeller plate thick is 5mm,what is the sutable motor and how cen i calculate the fan capacity, tell me the calculations with Exa also.