In case of motor Power Factor Generally We Apply A Capacitor
But How Can We Know That A Motor is Running On Very low Power
Factor And What Rating Of Capacitor We Have To Place And Tell
Me Conversion Of Micro Farad to KVAR>

Answers were Sorted based on User's Feedback



In case of motor Power Factor Generally We Apply A Capacitor But How Can We Know That A Motor is R..

Answer / pv2766288

generally now a days power factor is maintained by APFC ( auto power factor control) panel. Here there is a provision for setting the PF say 0.99. Capacitors from the capacitor banks are automatically switched off & on as per the load to maintain the set power factor. As motors are always run through motor control panel. As for the individual motor, we have to maintain the load for a suitable PF. Also C = kVAR / (2 π f V2) in microfarad

Is This Answer Correct ?    0 Yes 0 No

In case of motor Power Factor Generally We Apply A Capacitor But How Can We Know That A Motor is R..

Answer / bikkinas

According to its operating efficiency and output.

Is This Answer Correct ?    0 Yes 7 No

Post New Answer

More Electrical Engineering Interview Questions

What differance between Circuit brekar and Isolater?

14 Answers   TATA,


what is the function of commutator in dc motor?

10 Answers   CTS,


Why Motors are generally supplied with 3 core cables??? why not 4C??

5 Answers  


What is the difference between INVERTER and UPS?

7 Answers  


In a d.c current, the power is the product of voltage and current. This relationship does not always apply to effective(r.m.s) values in an a.c circuit. Explain the reason for this.

2 Answers  






What is the working principle of CFL & T5 tube light & 40W tube light with electronic ballast?

0 Answers   Remi,


Define filter?

0 Answers  


why the earth pin is thicker than other pins in a plug? If it is for reducing resistance, then why the copper earth wire is not so thick as earth pin of socket?

5 Answers   Omax,


WHAT IS THE USE OF TERTIARY WINDING IN A STAR/DELTA TRANSFORMER ?

3 Answers  


Can HT cable(11kv cable) be used for 415V, 700A requirement.

5 Answers  


why we can not use dc in our country( INDIA)

5 Answers  


why transformer rating is in kva?

11 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)