Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why single core HT cable need only one side earthing?

Answers were Sorted based on User's Feedback



why single core HT cable need only one side earthing?..

Answer / sreekantareddy

Due to circulating current

Is This Answer Correct ?    3 Yes 0 No

why single core HT cable need only one side earthing?..

Answer / munir1206

If we do shielding of cable on both ends then shielding will
become the conductive path for earthing and much more
current will pass from the shielding may be more than the
capacity of the shielding could damage the shielding, and
may introduce additional electromagnetic interference in the
cable

Is This Answer Correct ?    2 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

Transformer how to maintaince a check b check c check d check

0 Answers   DIC India,


what is the method to calculate the voltage drop for number of meters Example 250volts I/p at one end if the cable length is 50 meters what could be the drop?, after 100 meters how much? needs formulae.

1 Answers  


what happen if drive input fail momentry at 48.5 HZ frequency?

0 Answers  


while buying 30 kva on line ups for 1 phase ouput, we ave to calculate the number of batteries for 2 hours back up? how to calculate the ah rating and number of batteries

1 Answers  


why there is 1 phase and 3 phase but not 2 phase and 4 phase?

3 Answers  


what is the reason for earthing static equipments? why?

3 Answers  


What is broken wire condition in transmission line?

2 Answers   TATA,


Is it possible to obtain 480v or 550v in single phase output by giving the input to 230v to a single phase torodial type transformer without using a stepup transformer?

0 Answers  


How the PF control while running DG set with load

0 Answers  


what is electricity.

6 Answers   HP, L&T,


two bulbs of 100w and 40w respectively connected in paralel across a 230v supply.which bulb will glow bright and why?

4 Answers  


what is relation between HP & BHP

3 Answers   Usha Martin,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)