what is difference between co-generation and captive power
plant?

Answers were Sorted based on User's Feedback



what is difference between co-generation and captive power plant?..

Answer / subbu

Captive power plant means generating power that can be
utilizse home load and also can be export to GRID with out
utilizse the steam.

Co-generation plant means generating power that can be
utlisize home load, can be export to GRID and also
utlisizing the generated steam

Is This Answer Correct ?    13 Yes 2 No

what is difference between co-generation and captive power plant?..

Answer / k.prakashchandra

In short, co-generation means making use of waste heat
energy for generation.Captive power plant is for self
consumption during main supply failure from the supplier.

Is This Answer Correct ?    13 Yes 4 No

what is difference between co-generation and captive power plant?..

Answer / drk

Captive Power means Self consumption and Co generation
means use of heat for more than one energy including
electricity

Is This Answer Correct ?    7 Yes 6 No

Post New Answer

More Electrical Engineering Interview Questions

what is the potential difference between line and earth?

11 Answers  


what are cable earthing and bus earthing trucks?when and where they are used?

1 Answers  


Why in ESP Positive earthed

0 Answers   Sonhira,


Dry type transformers

0 Answers  


what is the significant for using two types of voltage(line voltage & phase voltage)

1 Answers   NTPC,






which gas is filled in CFL

7 Answers   Lumax,


11Kv Dog conductor 6/0.186 formula Line Losses ? Length 4.85Km amper ..? 52 Pole Max Load 3200Kw

1 Answers  


can we choose current transformer secondary, to calculate residual flux in a power transformer, so as its saturation is close to the saturation level of power transformer?

0 Answers  


why we use REF and Differential Protection in one transformers?my doubt is both protections are operated in internal fault only.why we want to use 2 protections?please clarify.

7 Answers  


how many joint can done in HT line and what is life of the joint

0 Answers   Micro Labs, Reliance,


We have 90mX100m hangar with 16 no.of supporting pillar. It is required to provide power supply on all pillars. what is suggested earthing scheme for hangars.

0 Answers   HAL,


Dear Brother can u tell the proper size selection of cable & the fault level calculation of braker, busbar etc. pls mail me at azeemk30@gmail.com

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)