why DC motor body is plain cover but AC motor is different
like finse?

Answers were Sorted based on User's Feedback



why DC motor body is plain cover but AC motor is different like finse?..

Answer / avd

In AC motor load current flows in stator and causes heating
of stator. Hence to cool it down fan is provided which
cools the body. To increase area fins or plates are there
on body.

In DC motor load current flows through armature, causes
heat generation in armature. To take out the heat you need
to cooldown armature. Stator cooling is not required, hence
plan body is okay.

Is This Answer Correct ?    7 Yes 0 No

why DC motor body is plain cover but AC motor is different like finse?..

Answer / yagnesh

only for cooling purpose ac motor has out side cooling fan
while dc has insite fan because we can very the voltage of
armature not of field so heat is generate is there so
require to cool the armature not field in ac motor
viceversa.

Is This Answer Correct ?    2 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

What will be the average KVA rating of Auto Transformer for 75kw 415V , 3phase induction motor

2 Answers  


Pls explan the OLR setting in VCB at HT yard

0 Answers   Juniper Networks,


1.What is captive power plant? 2.What is national grid?Give brief idea.

0 Answers  


How to calculate the size of the cable? for exp i want to use the load of 10HP

4 Answers  


dear sir/madam i want to get some knowledge about RRB EXAMINATION(section engineer) 1- what is minimum cut off 2- wht portion is major portion . 3- can any body provide Sample paper. thanks & regards ashish

0 Answers   RRB,






Advantages/Disadvantages of earthing of neutral bus on MSB instead of separate neutral earthing for transformer/DG sets feeding to MSB

0 Answers  


The ripple frequency in output of fullwave bridge rectifier is a. Half the input b. Twice the input c. Same as input

0 Answers  


When we have earthing mesh or underground earthing network in industrial plants, weather we have NT-S or NT-C-S kind of earthing system, so eventually weather we must use 4 or 5 wire in 400 volt level (For example 3×150+70 mm2 or 5×150 mm2) in this connection I would like to know exactly the paragraph of IEC or IEEE number

0 Answers   TATA,


how do you tell if a avalanche button diode is a p or an

1 Answers  


what is settable hystersis protection? If any body knows plz kindly post the answer..

0 Answers  


what is meant by armature reaction & where its happen ?

3 Answers  


Megar test tell sufficient resistant

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)