Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...



Engineering Interview Questions
Questions Answers Views Company eMail

how to do sudoko puzaals?

2278

what is reactive poower

3 5314

can you suggest good traning institute in instrumentation ? (in automation, or designing)

5 9185

What is the difference between lap splice length and development length of rebars?

4 31802

Required Qty of Cement Mortor for 3"x3"x1' groove filling?

2 5170

As electromagnetic waves travel in space only one can happen absorption attenuation reflection refraction

4 11257

directional relay is typically used to respond in fault condition who it can be used just as reverse power protection which purely senes direction reversal to operate a circuit breaker?

1 4001

how will u count the number of leaves in a tree by designing a circuit?

2 5105

I have carried out wiring for lighting in a shed in Industrial area which contains Metal halide lamps & have balanced in 3ph.Now when we put all the lines on in the daytime the current taken at 3phases at MCB comes to be equal i.e.28,29,28Amps respectively but in the night time i.e between 7p.m.to 11p.m. at the same MCb the current is 52,59,62Amp, though I have fit 63A MCB it is tripping in the above period.What may be the reason.? Note: This industry is located in industrial area where majority of steel ingot manufacturing plants are there. Whether this may be due to harmonic? what should I do to overcome above problem.pl suggest urgently.

4 6631

how to measure low temperature(<100 dec celsisus) with non condact sensor

2 5627

is oil viscosity affect on motor current?

2002

HOW CAN I WRITE the SCENARIO , USE CASE , Hierarchical Task Analysis AND PLAN FOR ATM ? URGENT

2287

write a c program to find the multiples of 5 usin arrays

1 4386

What is capacitor and its function?

7 13601

If I want to replace a 26KW Slip ring Motor with a Squirrel Cage motor & Drive (for a Hoist Application). How can I approximate the Motor & Drive HP required in new Setup.

2273


Un-Answered Questions { Engineering }

in aviation, How does control valves work?

1915


What does quality factor depend on in resonance?

1098


Action plan to closr NCR (NON COONFORMANCE REPORTS)

2294


If we want to change a contactor of faulty one what are the conditions want to fullfil

2001


How many VSC based HVDC are there in India and the world

2241


What is coaxing ?

1302


what is the ms flat constant for calculating earth mat design calculation?

2523


Define what is carbide?

971


What is construction mitigation management?

2335


What is the difference between AC and DC injection methods for rotor earth fault protection

2234


How to Preparation of online test

1696


why do we lay up the core of a cable?

2020


My vendor filled liquid oxygen in our 11000 liter capacity tank. He filled from 1400 MMWC up to 3200 MMWC. I followed the provided conversion table and found that we had been supplied 1800 MMWC liquid which is going to yield 2815 cubic meter. On the other hand, the vendor claims that he supplied as follows:- 5236 cub mtr(3200 MMWC)-2124 cub mtr(1400MMWC) = 3112 cub mtr. I fear that he wants to charge 297 cubic meters extra. He claims that my method was wrong and his was right. He says that this disparity is because of the conical shape of the base of the flask. I will be thankful if somebody can explain me the truth.

3356


Explain the role of nitrogen in welding.

1092


how do link aT1 from the 1st BTS to 2nd BTS4?

2062