Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...



Engineering Interview Questions
Questions Answers Views Company eMail

A 3ph load of 10 KW is equal to how many KW of single phase .

1 5955

What is skin effect?

1 6275

how do you tell if a avalanche button diode is a p or an

1 3565

I have iti elec, 1st aid, and 5 yrs experience in 7.5 mw power plant. Am i eligeble for 11kv license in telangana state..when, how to apply for that.?

2313

How to find weight of steel in kg if we know the area which is in m2? Following details are known to us, Area=125m² thk of slab=250mm Steel details:T12@200 PS:considering mesh top and bottom with X and Y direction

3099

What is the formula of vabration sesore. i mean how to covert mils to volt plz share if any body knows   very argent : my mai is merajalam143545@yahoo.com

Samsung,

2518

what is the wait of cement in different concrete mixes from M15 TO M50

L&T,

1 6427

what is difference between design mix and nominal mix,where the design mix is used?

2 7260

How to calibrate radar lt type transmitter

NTPC,

1 7384

In cement making,what is meaning of blend,fineness,density. 

UltraTech,

3527

What direction of rotation in crank? why not it rotate opposite direction?

1 4458

how can we judge the percentage of load on the basis of temperature differences readings between WTI and OTI in a transformer

Toshiba,

1 5054

jkms flip flop applications

2 5753

What we change frequency from transformer. yes or no

Intas,

3 7046

What is induction motor

Indoco Remedies,

1 5337


Un-Answered Questions { Engineering }

What is the crank length in the slab?

1081


How engine design needs to be changed to burn lean mixture ?

1058


What do you mean by distribution transformers?

1165


hallo I am looking for technical theortical knowledeg in air flow inside pipe and tunel's such as resisten of surefa's calculation and sempal's of calculation hopethat some budy can halp my thank you from devas

2357


1. Describe a time when you anticipated potential problems and developed Preventive measures.

2202


What is lmo? State some of its importance.

1134


i am studying in final year can i allowed for 23rd UES of Indian army

2124


Will an earth leakage trip be activated if the component or wiring is faulty on low voltage equipment.Example An electrical Cat Scarer placed in the garden and water gets into the wiring.

1868


What school did you attend in engineering?

1093


in HT service 3ph 4 wire service Y-phase voltage shows zero . whether it is meter fault? or what be the reason ? if y-ph voltage zero ,can current is recorded? reasons for failure?

1937


Give an example of a time when you had to explain some new procedures to your co-workers for quality service delivery. How did you go about it?

3188


DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

1008


Define what is the minimum temperature for stress relieving of astm a 519 gr.4130 material and please tell us where we can find the location.

951


explain types of electric welding and its applications

1799


how the synchronizing is obtained at bus couplers in grid substation? (because there we cannot change the frequency in one of transmission lines like in generator synchronization)

2377