Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379) How to design a Unit auxiliary transformer for a power house having a unit of 65 MW and Generating voltage of 11 KV and Secondary voltage of 433V
2137By cascading LPF and HPF active filter, the resulting circuit is A BPF B Narrow BPF C Wide BPF D All of these
3 9607The magnitude of the gain or integrator transfer function using op-amp is A WR1Cf B -1/WR1Cf C -WR1Cf D 1/WR1Cf
1943If R1=R2, then B=0.5, the total time T of square wave in astable multivibrator using op-amp is A T=RC B T=2 RC ln 3 C T=2 RC ln 2 D T=2RC ln (1+ 0.5)
2417A multiplexer, with 3-bei data select inputs, is a A 4:1 multiplexer B 8:1 multiplexer C 16:1 multiplexer D 32:1 multiplexer
1 3145Minimisation of Boolean logical expressions helps to reduce A Space B Number of gates C Cost D Space,number of gates and cost
2 4421In 7-segment display system, zero blanking is used to blank out A All the leading zeros B All the trailing zeros C The zero in the MSB(location) D a and b
1 6390Why should not we run the IM in low voltage, if runs means what will happen?(for example instead of 400V we give 250V supply)
2 3958We have 2 11kv/433v transformers for 2saperate acb for mv panels and 1 bus coupler acb. Suppose I’ll close bus coupler what will happen or it will be share the load. Please suggestion and any modification required.
1 351210 hp motor ,7.5 kw ,960 rpm, full load current 15.5, delta connection so how much take current no load trial time. any formula please give..... second question :- what is different between brekar control wiring and motor starter control wiring
MSP,
1 7337When you received a RA Bill of contractor at HO duly checked and certified by Site In-charge, How to know at a glance it is complete in order, do have any one checklist format in this regard.
2 7036
What is center priming?
why you don not show protection and type of isolation in key single line diagram?
What are sleeve and cotter joint?
What is the major difference between Normal control loop and Cascade control loop and when to use cascade control loop?
Manipulation of dead wt. tester double piston type.
how to find impedance , mutual indatnce in transmission lines
Where is the maximum temperature in refrigeration cycle? a.Between evaporator & compressor. b.At Compressor c.Between compressor and condensor. d.At condensor
What is centre height in cnc lathe
how to size an expansion tank in chiller system ?
Why whenever a reciprocating compressor is switched ON or OFF it is put into unloading mode?
you consider yourself suitable for the post in EIL?
Can 4pole (3 phase+neautral )RCCB proper functioning in only 3 phase load (no neautral, no Earth) ?
Can you please send me the previous 10 years solved question papers of GATE ?
Test on three subjects Physics, Chemistry & Biology are to be conducted simultaneously the number of candidates for the tests are 68, 36 and 72 respectively. Candidates are to be seated in different rooms such that each room will have candidates of the same subject and the load on each invigilator be the same i.e. the number of candidates in each room should be the same what is the minimum number of rooms you need for the purpose
what is Retainer?