If I want to connect a capacitor bank on the HT side of a 11kV/415V, 3 phase delta-star distribution transformer to supply Reactive power to it..what practical specifications of a Capacitor bank that can i've??please reply..
2040minor loss due to sudden contraction 1>flow contraction 2>Expanssion of flow after sudden contraction 3>cavitation 4>boundry friction
1 3226the bubble tube parallel to the telescope of theodolite should be more sensitive since it controls a. vertical axis b. horizontal axis c. axis of bubble tube d. none of this
4 14377nitrates more than 45 mg/l in water lead to disease called gastroenterities motteled teeth polio none
1 5595cross hairs in surveying telescope are fitted in the objective lense at the center of the telescope at the optical centre of eyepiece in front of the eyepiece
2 6413shearing strength of cohesionless soil depends upon dry density rate of loading confining pressure all above
1 5473undisturb samples are obtained by direct excavation thin walled sampler thick walled sampler none of this
1 3038relation bet Coefficient consolidation Cv, time factor Tv, drainage path d, & time t is Cv=d2Tv/t Cv=d2t/Tv Cv=tTv/d2 Cv=Tv/td2
SSC,
2391
The Hardness of wheel(or)grade of wheel refers to the
wath is this mining of hlr
How to improve fuel cell in a distribution system?
What are the applications of cad?
At 50 Centigrade (Diesel oil) what is its cast?
Hiii.. i have applied for steel plant management trainee 2010 exam for stream mechanical... the pattern of the exam has changed.. a preliminary exam which consists of the engineering basics... can any one suggest any book for this... kindly respond to this...
What are some common methods for helium leak testing a vacuum system?
How to select a contactor? How many types of contactors are available
From what on-site components does the HT panel monitoring the bus-bars in a 11kV system take inputs?
The requirement for ASTM A217 Gr. WC9 castings for valves components like Body and Bonnet were Normalising at 920+/- 20 Deg. C and Tempring 780+/- 20 Deg. C The specification calls furnace shall be calibtated within +/-14 deg. C The Heat Chart shows minimum temperature for normalising 900 to 920 Deg. C, but maximum temperature 960-990 Deg. C Tempering 780+/-20 Deg. C is within limits and accepted. Casting having integral test bars, heat trated along with castings passed in chemical znalysis and mechanical properties. Since normalising maximum temperature is not meeting specification, where castings can be salvaged or renormalised and retempered to meet specification. Whether it will have affect on remechanical properties testing
Which mechanism is used in automobile gearing?
what is transient stability analysis means?
The magnitude of electrostatic force between two identical positive ions that are separated by a distance of 5.0 x 10– 10 m is 3.7 x 10–9 N. (a) What is the charge of each ion? (b) How many electrons are “missing” from each ion?
Explain how is natural gas better than lpg?
in one hour , one 200 excavator , how much quantity (mcube)can load ? soil is not hard not soft