Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379) I work on a electronic positioner transmitter 4211 at the field.I connect my multimeter in series to get the current output then I calibrate it to 4ma in 0% of position of the valve and 20ma in 100% position of the valve.My problem is in the field I get the correct output current based on my multimeter but in the dcs they only receive 40% in a output 20ma of this positioner.Then I try to simulate in this analog card and they receive the equivalent percent on the value that I simulated.Is ther any possibility to reset the zero and span of this positioner 4211 fisher.And what other possibility I can do to fixed this.This is my email add ( landicho_randy@yahoo.com )
4 9492i(1)= j0.5 p.u., i(2)= -j0.5 p.u., i(0) =j1 p.u. What kind of fault it is-- a)l-l ,b)l-l-g, c)l-l-l-g, d)l-g.
2 4462How the FM 200 System is work? Just give me a reply about the Fire Incident and then Suppression by FM 200 step by step? Regards, ZahIR Uddin Babar For, BAFFESCO
2067my data card only does run in my mobile so how can change it that it run other mobile & computer and i can stor data in my data card
2278i have level transmitter -400 to 0 range for steam drum application but i am unable to calibrate if installation of lt below lower tap what will be the effect ? and as per std wht is location of lt ,above lower tapping or below
1 4788WE ARE HAVING YOKOGAWA CENTUM CS 3000 DCS, 2 FCS AND 4 HIS " When the operation Download to HIS message appears: Equalize start. HIS0163 WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. HIS0163 ---- ERROR = 3 WARNING = 1 ---- Tell me, please, why and how to solve the problem."
6 25817If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?
2100
How does iron ore turn into steel?
Tell me what is shear rate?
In Traffic Manager, What is the Use for Zero (0) timeslot.
what is meaning of inverted beam.is it way to provide double mat in slab one at bottom and another at topif we go for provision of inverted beam. shall we construct structure with out plinth beam for us we have to construct small bus shelter
What is a torque converter?
What is DTR erection?
What happen if we install my pressure transmitter below the elevation of pipe in natural gas service?
what parameters should we check to reduce the power bill
How to operate a ac chilar plant?
How do I decide which is the best technology to solve my vibration isolation problem?
What are the types of windings according to the construction?
What is Droop? What is Step/Gradient Limiter in Turbine Governor control?
why incomer bay is required before transformer bay if there are more than 1 nos. of transformer bay.
What is an ac emitter resistance?
How do you ensure that production processes adhere to quality standards while maximizing output?