Question { ISRO, 13160 }

sir,
how to select the cable size, what is the parameters use
ang what is the formulas use for this cable size
calculations. please tell me.


Answer

The cable is depend upon the connected load and type of
conductor. there is no thumb rule of choosing conductor size.
1 sq mm cu carries 11A current. whereas Al cond. 1 sqmm
carries only 3 amp current. this can only be choose from
companies catalogoues.

Is This Answer Correct ?    2 Yes 2 No

Question { 5711 }

How to calculate the size of the cable? for exp i want to
use the load of 10HP


Answer

Sir, it is simple 10kw motor will take 14 amp current in
normal running of motor but at starting shall take about 5-7
times more in case of induction motor. so we will consider
the cable accordingly

Is This Answer Correct ?    2 Yes 3 No


Question { Power Grid, 5540 }

In a HT switchboard where Nos. of Transformers are
connected, how to decide Incoming cable size? Whether Cable
should be rated for connected load or maximum demand?


Answer

Cable shall be considered according to connected load.

Is This Answer Correct ?    3 Yes 0 No

Question { 15223 }

what is the significance of 3.5 core cable? or what does this
half core mean and why is it required?


Answer

3.5 core means three core for RYB and half core is for
neutral as per IS-1554(p-1). this is in LT cables only upto
1100vots.

Is This Answer Correct ?    8 Yes 1 No

Question { L&T, 15373 }

single phase can run in PVC conduit. Three phase can also
run in one PVC conduit. But two phase cannot run in one PVC
conduit. WHY? reply plz....awaiting your answer.


Answer

kindly re-chk the question.

Is This Answer Correct ?    0 Yes 4 No

Question { Areva, 17990 }

what are the advantages and disadvantages of oil filled cables
over XLPE cables


Answer

now most of the HT and EHV cables are with XLPE insulation.
earlier, in mid 70's HT cable are insulated with PILC(paper
insulated and lead covered. OIL is filled to reduce moisture
in paper. disd of PILC cables is very heavy almost double
the weight of XLPE cable but adv is the chance of voids are
very less in PILC cable. Lead is not ECO-friendly,it is
almost banned in europe, US and few countries in ASIA. Cost
is very High as compare to XLPE cable. whereas XLPE cable
are lighter in weight.Long life,easy to handle. jointing is
less costly.

Is This Answer Correct ?    5 Yes 1 No

Question { 8281 }

which connection is safer series or parallel?usually which
connection we prefer at home?


Answer

Parallel or Series connection, all depends upon the
requirement. In Homes, parallel connection is preferred
because the apparatus used in home is of same voltage level
like AC, Iron, Microwave, Tubes, Bulb etc. all the equipment
marked 220v Rating. whereas series connection is used where
Low voltage devices are connected to sum up to connected to
equal supply voltage.
Both are equally safe and harmful.

Is This Answer Correct ?    4 Yes 0 No

Question { MAHINDRA, 3548 }

fog produced due to?


Answer

i feel Fine dust particles in humidity majorly form Fog

Is This Answer Correct ?    1 Yes 0 No

Question { TATA, 4722 }

How can we calculate the rating of a cable with formula?


Answer

there is no thumb rule for calculating the cable rating. if
we know the total load and calculate the system current
required. then check the rating in chart and select the
cable accordingly.

Is This Answer Correct ?    3 Yes 8 No

Question { Sterling, 21593 }

what is the purpose of using semiconductors in HT cables


Answer

The use of semiconductor layer in cable is
1. avoid air filled bubles and compete round structure for
insulation.
2. It influence the magnetic field inside the cable.

Is This Answer Correct ?    5 Yes 7 No

Question { 3065 }

what is the multi strand cable size? 0.45mm is area of one
strand & 370nos of strand.


Answer

Multi-strand conductor is stranded conductor. i.e solid area
is divided into no. of small area's( 1 sqmm wire is having
14 strands of 0.3 mm dia. which gives equivalent area for 1
sqmm solid conductor). By stranding the conductor, total
circumference will increase as compare to single solid
strand. further, 0.45mm should be dia of single strand and
370 would be the no's of strand in the cable.

Is This Answer Correct ?    0 Yes 0 No

Question { Siemens, 11592 }

what is the rating of power
generation in india?


Answer

the voltage rating for generator is 20 KV. the same is fed
to station transformer for upgrading the voltage to 220KV.

Is This Answer Correct ?    0 Yes 2 No

Question { 4276 }

How to calculate the current capacity of the 3C / 1C Al/Cu
power cable???


Answer

as such there is no thumb rule which works in calculating
current carrying capacity of particular cable. you need to
know the rating(area of conductor). either al or cu. then go
through catalogues of any reputed manifacturer.

Is This Answer Correct ?    1 Yes 0 No

Question { 4817 }

Under Ground Power cable earthing is required at both end or
single end? and reason for the same


Answer

Only one end of the armoring of cable is to be earthed to
avoid circulating of current produced due to magnetic field
of the conductor.

Is This Answer Correct ?    1 Yes 0 No

Question { Sony, 32573 }

How to sell the Product to New Customer


Answer

We must show him that product is useful to him and how he
will get benefit from using this product.also ensure the
correctness of price as compare to benefits of this product

Is This Answer Correct ?    18 Yes 2 No

 [1]   2    Next