How to find Viable Bacteria Detection using simple method?
Answer / juju
A rapid and simple method to measure total viable bacterial
counts are done using flow cytometry (FCM) and fluorescent
dyes in pureculture systems. Fluorescent dyes SYTO 63 and
TO-PRO 3 were the most suitable for the delineation of
total bacterial counts and dead bacterial counts,
respectively, and stained bacteria were counted by FCM.
| Is This Answer Correct ? | 1 Yes | 0 No |
why OD measurement for bacteria should be under 60 ?
Describe the antiviral activity screening facilities ?
How to do phage titrering ?
How the e.coli survives?
What is âfâ factor?
what is the method for seperation of periplasmic proteins ?
How RNA is prepared for mycobacteria?
Which iodine compounds are used in antiseptics?
what are the Advantages of Protoplast fusion ?
Why are mycobacteria acid fast?
What is acid fast staining?
Explain the Phosphate estimation?