Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

What is the mulplying factor of trivector meter (11kv) having ct ratio 100/5 amp.

2 3028

Which type of transformer used in lighting load?

IMFA,

2 3356

Please explain the following and how these are working with PLC unit 1.I/O Module 2.I/O Device 3.Adaptor Card 4.Ribbon Adaptor 5.RS 485-FC

Shree Mayur Engineering,

1549

what is the practical application of full adder circuit?

College School Exams Tests,

1813

How to calulate Locked rotor amper(LRA) for compressor type motors?

MAF Dalkia,

1727

how we can decide that what value of ht line will come to any commercial building? (ans except According to the building load)

1608

How does a clampmeter measures dc current

1 2763

Does Rheostat can use for power factor correction?

GOMS,

1 2954

we have provided 30 mA rccb to water cooler.but we feel shock in cooler body.what is the reason?

FCC,

3 4589

What is dry and wet flashover.

1 3636

What is meant by pilot exciter and its working?

2 8464

if vcb make contact but output notreach give the reason?

VVF India,

2 3352

my diploma certificate in my higher education college

Aastha Spintex,

1579

I am having a 1500 KVA transformer whose secondary current is 2086A and my connected load is 1000 KVA, I am having 400 KVAR APFCR for PF improvement what ratio of CT should i install in LT EB Bus to get optimum PF improvement?

1700

I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1641


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

explain the Trip supervision circuit

2103


how can we select the appropriate VCB ?

2256


how braking & making capacity of circuit breaker is calculated?

1968


If Dg set load increase 25%, How much increase fuel Consumption (15 kva 2 cylinder DG set)

2207


What do you mean by reach and reach the point of the relay?

1219


what is current check gurd relay?

2537


In control room of our one plant there is a continuously the incoming power goes to PC is vary,means in stabilizer it continuously indicate from high input to low and low input to high. what is the reason and its solution.

1927


why we dont prefer ac voltage controller instead dimmerstat [if both have same rating] for conducting experiments in laboratories?

2112


who many types of fire explane with exmple

2170


hai friends i have BSNL JTO exam on next month so if any body have model question paper or give preparation tips to my mail id kumar4486@yahoo.co.in this will helpfull for my future .plz & thank u by kumar

1955


c++ write a program to use a fuction call "max"which accepts an intger arrey of size5.as an arrument and return the larger and smallest of the arrey to main without changing. the original changing of the original position of the element of the arrey.

1879


hi,every one, i have to write the search paper on "performance policy optimization" of NGN (next generation networks). i need the material on this topic. can any body help me. please tell me any useful site where the good material is available and name of any reference book. it should be a great help for me.

1888


for compensate 315mh inductance ,how many capaciance required?

2011


When calculation of fault current and fault Kva is to be done,why always we use per unit value and why we consider the base kva?

1863


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2179