Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

In power plants the reading changes abruptly to give value (MW -25) (MVAR -15) What are the reasons for this? What is the solution?

GE,

2 4789

what is the difference between AHU and FCU .

JLL,

1 7002

What is the maximum allowed kwa through 2.5mm cable. Electric company installed 2 electric meter at my premises . Two jumper wires of 2.5 mm are used to connect . 2 single phase meters with allowable load 6 and 3 kwa. These jumper wires are taken from a 3 phase electric meter. Meters are in open Sun. What max load these wires can take.

KESC,

2168

I am new guy as an electrical engr. in a 100MW HFO based power project. I am in operations division. I have noticed from last few days, my supervisor sends the last 24 hours energy generation calculation to my plant manager. I have noticed, he calculated last 24 hour's generated energy differences in KWH then he multiplied it with a multiplying factor 960. for example: total difference =2.685 KWH*960= 2577.6 MWH. but he does not not know what is multiplying factor 960?? can anybody explain it??

Orion,

1 3698

what are the advantage and dis-advantage of 3 phase 4 wire energy meter?

2189

what is the dis-advantage of 3 phase 3 wire energy meter?

Exide, Nelco,

1 4869

where can the transformer having vector group Yny0 be used??

GK Power, NEA, Petrotech,

4124

what is power load and lighiting load?

2 4973

what will happen if secondary of potential transformer (220kv/110volt) of any metering core or protection core (cables) of any phase got earthed??

1 4542

what is the pulse and audio frequency transformer? what is different between induction regulators and tap changing transformer?

2111

A 3-PHASE TRANSFORMER IS USED TO STEP-DOWN THE VOLTAGE OF A 3-PHASE, 11KV FEEDER LINE. PER-PHASE TURNS RATIO IS 12.FOR A PRIMARY LINE CURRENT OF 20A, CALCULATE THE SECOUNDRY LINE VOLTAGE, LINE CURRENT AND OUTPUT KVA FOR FOLLOWING.A)STAR- DELTA.B)DELTA-DELTA.

Ispat, Red Bull,

3061

Dear Friends, Need your help for connecting APFC panel, Quotation : I have 2 No’s 1000 KVA Transformers, both transformers are having separate APFC panels, ( Tr-1,400KVAR, TR-2,450 KVAR) Now I want to stop One transformer, present load is 650Amps, Max, So One transformer is enough, I have switched OFF TR-1, but PF is not maintaining properly, its 0.5, So now I want to connect TR-2 APFC also in TR-1 Loads, Can any one answer for my Quotation with drawing, how to connect TR-2 APFC panel in TR-1 Loads,

L&T,

4 6640

Hi to u all : Friends: Why when operate on 2 phase welding machine the power metr goes reverse ?? the meter is god on other loads. thanks

Gedco,

2 4561

what is motor capacity of 80TR chiller? and also say what is the formula related temperature, motor capacity, TR?

Apotex, Periyar Chemicals,

2275

WHAT IS SPEC OF CLEANROOM MOTOR AND LIGHT FITTINGS?

Apotex, JLL,

2313


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Explain how you intend to work under pressure to meet up with deadline target?

5226


What does the letter CTNM in negative phase sequence relay means?

1812


Why collecting electrode of ESP to be earthed

2152


Why synchronous motor is used in power factor improvement,dc series in lift

1663


and gate circuit diagram,amplifier circuit diagram

2069


What happen to generator if i have unbalanced load?

2105


How does a digital electronic meter work??????

2060


Please, if 1kw is equal to 1.25kva; how then do I know how many kva in 7.5kw?

1660


FEINGING DECREASES THE FLUX DENSITY IN THE AIR GAP. HOW?

2191


What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer

2376


why incomer bay is required before transformer bay if there are more than 1 nos. of transformer bay.

3111


Explain what is electric traction? Explain few advantages of electric traction system?

1158


The shot circuit in any winding of transformer result? Explain

1339


Define thermal resistance in the context of power amplifier.

1127


What is the mechanism of WTI

1801