In power plants the reading changes abruptly to give value (MW -25) (MVAR -15) What are the reasons for this? What is the solution?
GE,
2 3356What is the maximum allowed kwa through 2.5mm cable. Electric company installed 2 electric meter at my premises . Two jumper wires of 2.5 mm are used to connect . 2 single phase meters with allowable load 6 and 3 kwa. These jumper wires are taken from a 3 phase electric meter. Meters are in open Sun. What max load these wires can take.
KESC,
1513I am new guy as an electrical engr. in a 100MW HFO based power project. I am in operations division. I have noticed from last few days, my supervisor sends the last 24 hours energy generation calculation to my plant manager. I have noticed, he calculated last 24 hour's generated energy differences in KWH then he multiplied it with a multiplying factor 960. for example: total difference =2.685 KWH*960= 2577.6 MWH. but he does not not know what is multiplying factor 960?? can anybody explain it??
1 2600what will happen if secondary of potential transformer (220kv/110volt) of any metering core or protection core (cables) of any phase got earthed??
1 3619what is the pulse and audio frequency transformer? what is different between induction regulators and tap changing transformer?
1486A 3-PHASE TRANSFORMER IS USED TO STEP-DOWN THE VOLTAGE OF A 3-PHASE, 11KV FEEDER LINE. PER-PHASE TURNS RATIO IS 12.FOR A PRIMARY LINE CURRENT OF 20A, CALCULATE THE SECOUNDRY LINE VOLTAGE, LINE CURRENT AND OUTPUT KVA FOR FOLLOWING.A)STAR- DELTA.B)DELTA-DELTA.
2029Dear Friends, Need your help for connecting APFC panel, Quotation : I have 2 No’s 1000 KVA Transformers, both transformers are having separate APFC panels, ( Tr-1,400KVAR, TR-2,450 KVAR) Now I want to stop One transformer, present load is 650Amps, Max, So One transformer is enough, I have switched OFF TR-1, but PF is not maintaining properly, its 0.5, So now I want to connect TR-2 APFC also in TR-1 Loads, Can any one answer for my Quotation with drawing, how to connect TR-2 APFC panel in TR-1 Loads,
L&T,
4 4741Hi to u all : Friends: Why when operate on 2 phase welding machine the power metr goes reverse ?? the meter is god on other loads. thanks
2 2891what is motor capacity of 80TR chiller? and also say what is the formula related temperature, motor capacity, TR?
1630Post New Electrical Engineering Questions
sir please send me iocl written test paper in my e-mail account. i'll be obliged to you........ thank u roshan
What is an iron loss or core loss pi?
physical identification of HT & LT panel
what is the prosses for getting of 33kv licence (i have completed my engineering degree & working in 33kv substation for contract basis )????
how to calculate mf when meter and cTPT detail are given
diff.between servo motor and ac motor
What is the actual meaning of thermal power efficiency ?
how does an centrifugal and screw type chiller will work. which chiller efficiency is high and why.
hi if anybody got model questions for cpcl Grade'A' electrical engineer position.send it to my mail please krishkumar22@gmail.com
What are the material used for inductance coil?
why ht motors are star connected?
in a silicon diode we can measure .7v in a voltmeter.but why we can't use this voltage for using?
at which voltage level arcing ground is occurs ??????????
Explain Random and Deterministic signals?
why we use 630mm single core cable for transformer secondary side and why two neutral cable