why is electricity produced and distributed in multiples of 11. 440V, 11KV, 22KV, 132KV etc
Bhel,
2 7311A double circuit with dog conductor 66KV Transmission line from wind farm evacuation to feeding substation having capacity of 25MW for transmission. Can same transmission network be considered for further expansion of Power & how much in MW. If we need to expand next 10-15 MW more will there any augmentation is required in transmission network? Kindly reply asap.
2195how can we find thae value of capacitor for single phase motor. what is difference between starting capacitor and running capacitor.
2368Is there a chance for a motor speed to become negative..?? What is the reason for such a phenomenon.? In that case does the motor works as a generator..???
1 3521What is ESP how its work &what is corona ? con insulater&drive insulater where it is used ? Any body says that pls
3 8378Post New Electrical Engineering Questions
should %impedance be high or low in a power transformer? if so why?
what is the effect of vector group while phase sequence of a generator changes,whether the vector group changes or not
What is a commutator?
In how we connect watt meter for open & short circuit test of a single phase transformer.
What is UPS and How do you maintain the UPS Maintenance? Brief Description on UPS maintenance.
how can we find thae value of capacitor for single phase motor. what is difference between starting capacitor and running capacitor.
can any one suggest me the tilt angle of my solar pannel ?? or tell me how can i know the fix tilt angle of my solar pannel?? my cordinates are 31.503629,72.993164.
Why and when NGR panel required. Is it necessary to design a NGR panel for a 6.6kV Alternator paralleling with Grid????
operation of protection relay watchdog contact?
How much load can be taken for chiller from 1500 kva transformer
What is Scheme Test of High Voltage Switchgear. Which tests it includes.
State magnitude criterion.
What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.
I have a 380 KVA DG set. How can i find out 1. My Fuel Consumption per hr ? 2. Electricity produced in 1 Hr. ? 3. If load varies then how does it affect fuel consumption & electricity produced ? Please HELP !!! Really need an answer.
working principle of AC Servo Motor with its construction