why the transformer neutral earthing is to be done by copper flat only,if we use GI flat what is the disadvantage.
2 8634In dc motor starter there is less voltage required for holding contactor that's may why it is called no volt coil. but in ac starter why holding contactor is called no volt coil.
JSW,
2 5766If there is unit power factor in a power house and a capacitor bank used in a factory at resistive load . In this case, will there leading power factor in power house across that factory.
2 4787there is a # KVA Transformer of 11 KV/440V, in simple(not use formuia) how can you calculate it's HT & LT side current.
5 24155i have 90kw motor.so i choose connect cable .please what is parameter checked so please give to formula
2252Post New Electrical Engineering Questions
How we can defined theecopper cable size if we know the aluminium cable size?
What are the types of control system?
how we decide wire gauge for ac or dc coil and what is the basic diff. B/w these two coil?
what is settable hystersis protection? If any body knows plz kindly post the answer..
How to design a Unit auxiliary transformer for a power house having a unit of 65 MW and Generating voltage of 11 KV and Secondary voltage of 433V
When color of silica gel will gets change from blue to pink from Top to bottom?
What is the difference in calculating size of AC cables compared to calculating size of DC Cables? Usually DC Cables are larger than AC Cables although they have the same ampacity. Why is it?
what is control supply rating of a machine
What is the real function of reverse power relay in generator panel while syncronising?
How does a television work?
Explain what is clipper and clamper circuits?
A powerplant has 8 gensets operating in grid parallel mode. In one genset sometimes there is pf variation and kvar variation. The plant operates in pf mode. When this variation is observed the load is stable, voltage is also stable, freq and genset speed is also stable. How will you check the functioning of pf card. What shall be the ideal output vdc of the pfc, from there it is input to AVR?
11kV capacitor bank of rating 2.4KVAR, is charged with protective relays of only over current & Earth fault &.......without Over Voltage, Under Voltage & Neutral Displacement Relay. Is it advisable??
how to calculate the no load current in transformer?
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?