why it is mentioned as 8/10 mva transformer why not directly 8mva or 10mva transformer. please explain me the full detailed reason.
4 9326Hi,iam a diploma in electrical engineering.rtd from indian air force in apr 2007.prsently working in reliance next link as a network maintenance engineer since 2007,can i get a job in motherson sumi.
2372in 11kv/400v transformer when only one phase of 11kv supply fails what happens to sec voltage and why
6 16288In a 3 phase induction motor(without connecting supply) if we rotate its rotor by hand and check resistance of stator winding at motor terminal box its resistance varies why ??
3 6594How I can Compare 120v/60Hz versus 220v/50Hz ? Please tell me both advantage and disadvantage ......
2026How the setting of the vector surge relay shall be calculated when the relay is to be used for Grid islanding application?
2261Post New Electrical Engineering Questions
Saving in copper achieved by converting a 2 winding transformer in to an auto transformer is determined by A voltage transformation ratio B load on secondary C quality of core material D size of transformer core
What is the difference between isolators and electrical circuit breakers? What is bus-bar?
What is essential to prove safe isolation of electrical circuit?
whats the application of voltage regulation? and whats the voltage regulation's device?
How to calculate VCB rating for 33KV ,25 MW Power line?
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
Dear sirs, pls check this 4-20ma to RS485 module datasheet,pls guve me some suggestions. http://www.szsunyuan.com/sy/pro_more.asp?Productid=539 Thanks. E-mail:yunianjiang99@gmail.com
List of equipments required foe industrial repair lab.
will 1050kva DG set withstand for back charge of 16MVA transformer
What will happen if the d.c. Shunt motor opened accidentally running on no-load has its shunt field winding?
What are the factors which influence the choice of specific magnetic and electric loadings of a synchronous machine?
define the active power?
What is the transfer function?
How do u analyse protection fault when vcb tripping on load
what is a synchronizing lamp ?