Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

Graphs of measuring power and speed on dc motor

1927

i have one source transformer with the capacity of 50KVA, connected with two loads 10kw and second one is 15kw.. how can i calculate first load in KVA and second one in KVA .. because Kva rating, power factor rating of of transformer is different from the load… there must be some way to calculate load KVA rating and power factor….

1 3897

how capacitor can split the phase.

1 3873

Give me clear explanation.What is the Different Between Load break switch and Vacuum circuit breaker

1 3969

Can we Co-ordinate relay in Load Break switch?

Bhel,

1924

in conventional fan regulators how the current varies with speed?

1945

why transmiision rating in kva?

4 5722

i(1)= j0.5 p.u., i(2)= -j0.5 p.u., i(0) =j1 p.u. What kind of fault it is-- a)l-l ,b)l-l-g, c)l-l-l-g, d)l-g.

Areva,

2 4350

can we run AC & DC cables in same tray

Aurobindo,

1 3230

how we select the mva rating of the circuit breakers?

1 3797

how to size H.T & L.T Panel ?

Schneider,

2091

How much amps carry in single phase R-phase,in D63A 4-pole MCB

TCS,

1 5942

we have total 1000hp motors we paid 7 laks rupees how to reduce power bill

4 6318

How much earthing frequency is capable?

1922

how does WTI work ?

1938


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Difference between drift current and diffusion current?

1825


My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I -    is the value of AC fault current. t -    is the operating time of disconnecting device in seconds. K –  is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.

1825


What is power relay?

1199


Draw a SLD of HT distribution EB grid up to users Transformer?

6166


diff. between tension mode & speed mode

2280


Thumb rule of cable size(rm>30 rm)X multiplying factor=ampere

1568


Difference between low impedance and high impedance Restricted Earth Fault

3084


what is the difference between earth leakage and earth fault?

2261


how is capacitor bank look like

2354


What is the phase relationship between the primary and secondary voltages of a transformer?

1041


Define active and passive network?

1090


How to calculate total harmonic distortion level(THD) in VFD? and how can we reduce harmonics?

4009


Why the efficiency of a three-phase induction is the motor is less than that of a three-phase transformer?

1098


What is George phenomena to start the synchronus machine?

4101


How the frame size of a flange mounted AC induction motor is calculated?

2022