Will it be OK to connect a 5MVA 33/6.6kV Ynd11 Transformer to a Star connected Motor. Or on other words connecting a Delta to a Star. I have another 30MVA 33/11 Dyn11 and would it be practical to convert it to Dd0 consequently converting the Voltage Ratio to 33/6.35kV Dd0.
1 5470In synchronous motor, how the field current is related to armature current..i know its inversely proportional..but concept wise...i was nt clear....pls help me...
2045if field winding of synchronous generator are shorted on each other will it start or burn or run for short time like induction motor
1 3104Post New Electrical Engineering Questions
DG cranking voltage?
There are different classes of protections in power plants.class a,b,c are clear..is there any class d and e r there..and elaborate class b protection.
sir plz send some previous year questions of jspl.
-What shall be short circuit current of LV switchgear for a 1000 kva, 11.415kv, 3 phase tranformer with 5% reactance.
What are the advantages and disadvantages of the ac motors?
In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.
i had aplied Hindustan Petroleum corporation limited for the post of maintenance technician -Electrical,i want model questions,if anybody have please send it or please advice?
In vapour absorption refrigeration machine fluids used are
What is use of starter and choke in tube light
Is it required to do earthing in 2nd shop if earthed armoured cable is laid from 1st shop ?
why three phase capacitor takes unbalanced current in capacitor bank?
11KV AND 22KV NETWORK KW CAPACITY IN RING AND RADIAL?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
state basic meaning of 'INDUSTIAL AUTOMATION'?
What are the different types of dams?