Electrical Engineering Interview Questions
Questions Answers Views Company eMail

calculation of knee point voltage of current transformer?

TATA,

2 4822

can we use ordinary transformer in place of autotransformer?give reasons also

1 3944

primary of transformer connected to Dc supply in series with switch, and secondary connected on ammeter, what happens when swith On and OFF. (or) if continuously On and OFF

9 6888

why core of transformer in square or rectangular why not in circle or ellipse if this what happens

2 6970

why dont we use the same pylon to carry 400 kv plus 220kv and 33 kv ?

Focus, Focus Energy,

2 4536

"TRANSFORMER MODELING AND ANALYSIS" MEANS WHAT AND WHICH TOPICS U READ IN THIS

1407

what is the current setting for different relay protection for transformer .

Crompton Greaves,

1747

ADVANTAGES OF DIGITAL COMMUNICATION OVER ANALOG.?

Google,

1 3276

why ac current do not save

3 4924

why the earth conductor in top of the tranmission line ?

2 4022

explain Xmer

2 4151

how does a tube light choke working?

2 6535

how does a tube light starter works?

2 4109

what is the minimum voltage require to injure our body?

4 5645

whats the differece between Exd and Exe

IFFCO, TN,

4273


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

why high speed tripping relay will be used in tripping circuit why not normal relay

819


How to choose size of the cable w.r.to current carrying capacity ...

1674


how indusrial diesel generator work

1451


is it possible to say motor horsepower number without seeing name plate(when name plate damaged)

1578


I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?

1770






Can anyone provide with a SLD for HT panel installation for a 33KV line and distribution end has three 1.5MV transformers. Is it suitable to use OCB or VCB and also provide me the suitable rating and its connection diagram.

2879


what is the difference between dry and wet type of 132kV terminations. which one is durable

1544


A mass of 1200g is accelerated at 200 cm/s2by a force. The value of the force required is:(a) 2.4N(b) 2400N(c) 240 kN(d) 0.24N

2115


what is the need to express current and voltage in rms value? rms value is also called as effective value,what is effective value?

1476


What is the complete procedure of erection of electrical panel in industry

1364


What are the necessary components of the feedback control system?

717


Witch do depand of Power factor and theory of power factor?

1643


What is lc oscillator?

710


The moisture in air will condense at

667


Why 11kv to be generated in generation station

1244