I am looking for LV CT test. To check the polarity of the CT only. Can you suggest any supplier. Different companies are offering CT/PT Tester which is expensive. Thanks
2 4318WHAT DO YOU MEAN THE DIFFERENT TYPE OF CURVES OF RELAY LIKE STANDARD INVERSE, VARY INVERSE, NORMAL INVERSE, LONG INVERSE ETC....
1580What is the difference between single core 2 wire and single core 3 wire system? Which application we are using this? and for What purpose we are using this?
1897when i am going to take trail on a 3ph sq.i/m motor 5.5kw, i observed that RPM of the motor is very low as compared to the rated RPM and also it rotates in clockwise in first ON command,and anticlock wise in second ON command. finally i observed that on phase is no available . but iam not clear about, why the motor is rotates in both directions without any phase interchanging.pls answer to my question.
1 4660Our Alternator nameplate specifies a power factor of 0.8. When the Alternator is on light load, the bus bar voltage rises to 11240 volts, whereas the standard value is 10500 volts. Is it ok to increase the power factor to 0.85 or 0.9. I am afraid because the power factor on the name plate is only 0.8 ?
3 5406Post New Electrical Engineering Questions
wish of these transformer uses oil?
hi frnds can any one help me ? plz send me placement paper of IOCL of Electrical streem .... plz send ....its urgent....
placing earthing pit in pathway is correct or wrong??. placing earthing wireGI1/18 inside walls is correct or wrong?. explain!!!
A Generator is in running condition and Rotor earth fault alarm is coming.How to check on line(i.e in running condition) whether there is actual earth fault in rotor or not.
Refernce currents are to be generated using refernce cueernts how can this be done??
3ph motor running with unequal kw and different pf what are the reasons
how to identify conection leads of an unknown electric motor
Can a generator runs after getting 1st stator earth fault.
RESPECCTED SIR/MADAM- I AM PRERING FOR SECTION ENGINEER (ELECTRICAL) RRB CHANDIGARH PLEASE SEND ME SOME PREVIOUS YEAR QUESTION PAPER OR MODEL PAPER.MY EXAM IS ON (30- NOVEMBER 2008).I AM VERY THANKFUL TO YOU. FROM- HARENDRA SINGH YADAV
how to carried out DAR test in 11 KV Alternator ?
what is per unit calculation?looking for simple and strong explanation thk u
Why do we use center tap transformer that used with portable tools
What are the protections for safe running of electric generator?
When can we take Neutral as common neutral link?
Explain what is rated speed?