Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

who is invented transforner (230v).......

2 4861

How to run 1ph motor(230 VOLTS its full load amps is 4.5 ampa))with 480 volts main(we didn hav neutral)Thn we go for step down transformer.Our load 10 amps,so we conisder this amps in primary are secondary side

1 3730

how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING) I O (current operating)?

2208

why the all high voltage transformers are in 11kv , 33kv , 66kv, 132kv like that

Bhel,

2 7467

Why we does earthing for transformer neutral point

amps, DLF,

5 12174

which is dangerous AC or DC? If so why?

4 7056

why the check zone and main zone are used for Busbar Protn. scheem?

2185

why the undervoltage relay's interlock is used in earthswitch closing operation of the 400kV line scheme?

2 5588

Why should we use Star-Delta connection in step down power transformers?

L&T,

7 21097

now a shunt motor is practically a constant speed motor , then how does it meet the increase or decrease in the load ?

1 3430

how to varied the frequency in transmission line and how i kept it as a constant one?

L&T,

2 5544

what will happen to the core losses if we perform the open ckt test on high voltage side of a transformer ?

2 4800

What will happen if the interpoles in case of a generator have opposite polarities to that behind it in the direction of rotation ?

1 4291

if the armature current in a dc generator is ac ( sinusoidal ) why doesnt the sjhape af armature mmf a sinusoidal (ni) ? armature mmf in case of a dc machine is triangular.

1971

1.what is difference between line,neutral and earth 2.IF single phase voltage is 230v ac and what should be the voltage between line to neutral,neutral to earth and earth to line

1 6232


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Where can I get CPWD electrical specifications & Shedule of rates? Please help me

2257


What is difference between YNyn0 and YNyn ??

2559


Write the programming software name for LG, SIEMENS,Messung,AB

2036


are there rmu for 3 transformer?

1881


Please nybody say, weather the result of Bharat Oman is declared or not? Probable date of declare???????

2006


Can any body tell gulf interview question for experienced electrical engineer ?

2112


what is formula for zero phase sequence of nuetal earthing transformer of 6.6 kv

2290


all details of DG UPS HVAC

2078


Merits & Demarits of Oil circuit & Air circuit breakers ?

2080


What is depreciation factor?

2271


in HT service 3ph 4 wire service Y-phase voltage shows zero . whether it is meter fault? or what be the reason ? if y-ph voltage zero ,can current is recorded? reasons for failure?

1927


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1590


A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE

2585


why does make gain margin and phase margin on same plot.?

2118


how to find the Motor,s insulation Power?

1763