Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

what is allowed value of zero sequence impedancce of 6.6 kv nuetral earthing transformer ?what is the actual value

2117

what is ps impedance test

2076

how to do 'pole drop test' on AC generator?

1 24532

what is formula for zero phase sequence of nuetal earthing transformer of 6.6 kv

2249

please explain how to do 'pole drop test' on generator?

2869

Please explain how to do 'tan-delta test' on AC generator? and where i get clear and brief detail, give any web page address.

1 5270

hi... Can anybody give me description of type-2 coordination, IP protection, NEMA standards ? Thanks..

KSEB,

2 3759

what is p.s impedance measurement test in earthing transformer?

Greenko,

2365

What are the main factors to be considered(In terms of energy conservation) while selecting a new air compressor?

1 3572

In CT's they mentioned 400/5 or 1250/5, 1000/1 here 400,1250,1000 is Breaker Capacity what is the /5 Explain me briefly

2 5535

In DC while we mention the voltage we are using -48V but in case of AC we mention only 230V not -230V, why we using -48V not 48V

2 5017

when we see the lube oil grade its 15w/40 or 20w/40 in this what is W Explain breifly

1 4974

what are the advantages of Horizontal isolation breakers v/s vertical isolation breakers in medium voltage switchgear class.

NNN,

1 2846

CORRECT INFORMATION ABOUT TRANSFORMERS,what actually transformer is?

6 7575

what are the alternator cooling system? how it is represented?

1 3332


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

1- What is the Polarization Index number be good for 15KV 3c#500MCM electrical cable? 2- Can I use the IEEE Std 43-2000 to perfom the PI test? Thanks

3334


Installation resistance for whole installation of 16 kva & 25 KVA DTRA a) Between each conductor b) between conductor to earth c) installation resistance for each apparatus, each conductor to earth d) earth resistance for the system of earthing

1866


How can we increase fuel-power ratio of any DG set?

1776


How to check the LM324 Ic

8430


In control room of our one plant there is a continuously the incoming power goes to PC is vary,means in stabilizer it continuously indicate from high input to low and low input to high. what is the reason and its solution.

1928


When semiconductor fuse does save thyristor in each cycle of conduction? Why under voltage setting keep less in SPRS and more in DC drive?

2045


what is the diference between the 4pole & 6pole DC Motors & what is advantage 6pole over the 4pole ?

1969


Explain bypass capacitor?

1114


what is mppt (maximum power point tracking ) and how they used in solar power generation ??? what are the main components used in mppt?????

3274


Where is the best place to mount  distribution panel in a house.

2030


What are the components connected in between the power supply coming from an electric pole to HT & LT Panels in a large commercial building or how the power supply connected from Electric pole to Transformer & then to the HT & LT panels of a building? Please send me answers via mail, my id is yogiagarwal@gmail.com. If possible, please give a line diagram.

2030


explain single phase series motor

1901


how to find out cable size if load is 2800 watts, 230 volts AC supply and load distance is 1800 meters

1572


What is effect of over voltage and under voltage on ACB

1901


how to find the multiplication factor for digital energy meter and analog energy meter

2166