Is it alright to connect more than one RCCB of same rating in series for a three phase equipment?
3 4999a 11 kv line is grounded and a 110 kv line is grounded. which line have the greater current flow?
4 7388in india why 50 hz and 220 volt taken as standard rating for equipments whereas in US 100hz and 110v is consided as standard rating.is this method save power.
5 10018there are a transformer and a motor. both are connected to 3phase, 415 Volt, 50Hz power supply. Both are working with induction principles. Then, why, motor is rotating and transformer is not rotating.
8 12127Post New Electrical Engineering Questions
for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance
WE HAVE THE DC RECTIFIER 1500A, INPUT VOLTAGE IS 3 PHASE. HOW TO CALICULATE THE LOAD? 3 PHASE SIDE EITHER dC SIDE. PLEASE SUGGEST ME
Can the output voltage of a rectifier be greater than the input AC voltage without the use of any voltage multiplier in the circuit??please provide the explanation too..
Difference between earthing & grounding.?
What do you mean by a voltage transformer?
WE ARE PLACE A NEW 75 KW MOTOR FOR JPF.IT IS CONNECTED IN M.C.C. WHEN WE ARE STARTING M.C.C.INCOMER IS TRIPPED.THEN WE ARE CONNECTED IN P.C.C WITH A MM30 RELAY PROTECTION THEN WE ARE STARTED MOTOR WILL RUN SMOOTHLY.
what will happens if one phase is missing for 33/11kv power transfomer and why?
explain with diagram how to protect transformers and substations from over current with help of CT's?
which protection function should measure RMS value of current&DFT value of current?
How each of the following losses occur in d.c machines (i) copper (2)core (3) windage (4)friction please help me
Metal covered multiconductor cables shall employ a marker tape located within the cable running for its complete length in lieu of cable surface marking. Is it true or false?
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
what the Microsoft .NET framework is?
Phase control and integral control are used for?
what is meant by k-rating in isolation transformer?what is k9, k14 stands for?