Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

what is electrical?

15 16741

what is elcb

2 4740

can i use 4 number of circuit breaker as single phase manual change over switch? if yes then how plz also send ckt diagram at nazimzamurad@gmail.com

2129

What is the function of pulse transformer?

Electrotherm,

4 16206

how electrical energy is converted into mechanical energy in dc motor

3 7790

What happened when we give 2 phase supply to a 1 phase equimpent. It's effect on equipment's efficiency and life?

5 8340

What happened when a three phase induction motor work on two phase supply.9

6 9963

what is the Mechanism of energy saver FAN how average power,reactive power, power factor e.t.c realated to it and how it apply to this FAN .and how this fan save energy w.r.t circuit analysis,plz repaly to this question this is the assignment to given to me.thanks

1 3325

what is the diffrence between R Y B phase and why it is called RYB

5 24517

What is the main function of fuse?

7 30112

A Generator is in running condition and Rotor earth fault alarm is coming.How to check on line(i.e in running condition) whether there is actual earth fault in rotor or not.

1956

Do power transformers have an Automatic Voltage Regulator (AVR) just like the alternator/generator in a power system?

4 7140

how to check regenerative load in drived motor

Hindustan Unilever Limited, NHPC,

2231

what is diode? and what it is used for ?

3 5016

What Is HO factor in power selection

Wonderla Holidays,

2074


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

why and how current drawn by battery charger depends upon the altitude where it is located?

2039


Can we put 3 layers of cable tray while installing tray

2398


What do you mean by lighting transformer?

1056


Can we use Ccapacitive voltage transformer directly for metering purpose?

1863


In what cases (circumstances)we should apply P controller, PD controller, PI controller & PID controller ?

2183


DEAR SIR/MADAM,CLEARLY EXPLAIN ABOUT CRAWLING AND COGGING EFFECTS IN INDUCTION MOTOR.

1974


how to select electrical equipment such as fuse,dg,transformer,motor,msb,wire,cable as per the connecting load..please mention any books to design,take licence

2987


what is mean by dry frequency

2460


What is the typical enclosure type used for Indoor switchgear / Outdoor switchgear Units? - In Onshore / offshore Units?

998


In synchronization circuit what is the function of Interposing voltage transformer(IVT)and Reverse voltage transformer(RVT)

11831


WHAT ARE THE CHARACTERISTICS OF AN VOLTAG AMPLIFIER

2030


My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I -    is the value of AC fault current. t -    is the operating time of disconnecting device in seconds. K –  is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.

1880


ELECTRICAL DRIVES: can a motor load system with passive load torque can have equilibrium speed in second quadrant

6319


i have applied for junior engineer 2 c&w for Guwahati RRB please send me last five year question paper

2171


if voltage bt phase & nutral is 38v in a panel board . whats the root cause.

2314