can i use 4 number of circuit breaker as single phase manual change over switch? if yes then how plz also send ckt diagram at nazimzamurad@gmail.com
2076What happened when we give 2 phase supply to a 1 phase equimpent. It's effect on equipment's efficiency and life?
5 8178what is the Mechanism of energy saver FAN how average power,reactive power, power factor e.t.c realated to it and how it apply to this FAN .and how this fan save energy w.r.t circuit analysis,plz repaly to this question this is the assignment to given to me.thanks
1 3254A Generator is in running condition and Rotor earth fault alarm is coming.How to check on line(i.e in running condition) whether there is actual earth fault in rotor or not.
1901Do power transformers have an Automatic Voltage Regulator (AVR) just like the alternator/generator in a power system?
4 7020Post New Electrical Engineering Questions
i need about 10 years of GATE solved papers in pdf format and even mock tests toooo
What is the function of interposing current transformer?
i've iocl interview.. if you know the interview process please give me information..
why the pf of semiconductor device is improved the electrical devices
what is two point starter?
If any one's require of phoenix contact like( relay , termilnal block , surge protection device ) , product please contect me 09878206357 chetan verma
How does a digital electronic meter work??????
In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.
why star point of HT motor not earthed?
can anyone show me how the 3 phase power is supplied to socket outlets?
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
how to decide the panel size like MDB ,SMDB PANEL SIZES
WHY CBCT USE ONLY IN Y PHASE NOT OTHER PHASES
Is it required to lay GI wires along with GI/MS conduits from one point to another point though separate earthing cable is conncted from DB to Socket?
How do the synchronizing lamps indicate the correctness of phase sequence between existing and incoming alternators?