Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

How to decide DO set rating of Transformer?

1700

WHat is the requirement of installing FAST ACTING EARTH SWITCH in GIS and how is that integrated with protection system. How and when does it operate?

2243

How to Preparation of online test

1775

what is mean by D.O. in distribution line poles?

1752

How to calculate ht side cable of 630 kva oil cooled outdoor transformer?

1 2253

The shot circuit in any winding of transformer result? Explain

1394

What is difference between safe PLC and normal PLC

1687

What types of question are done for diploma students in aptitude test

1724

which cable is used for 15 Hp monoblock pump 3phase and service wire Distance is 210 feet please tell me cable size Armaured

1650

What is Meter MF if External CT Ratio is 150/1 , PT Ratio is 132/110 Meter CT Ratio is 200/1 & Meter PT Ratio is 110/1

1961

What is the function of a neutral reactor.

1930

How to assume answer to electrical questions

1580

11 kg trivevter meter has rating of -/5amps. And pt ratio11000/110v and is connected with 11kv ct/pt unit of cr ratio 75/5amps. And pt ratio of 11000/110v while checking accuracy of meter with HT Accuchek meter what value of PT ratio and CT ratio to be filled in Accuchek meter

1993

how to find Harmonics and types as per the equipemnts

1340

I have a CT meter with ratio 60/5. The meter reading of previous month was 3290.49 and that of current month was 3797.26. How many chargeable units as per normal meter should be my reading.

1462


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

How to calculate pitch, gauge of winding wire, and No. of turns for 30HP, 3 phase, 4 poles 50Hz, 380V induction motors

2008


How grounding is different than earthings?

1231


For high frequency application we use which transformer?

2013


what is the need of starter in tube light and what type of starter is used in that?

2097


What is the vector group of a transformer,how can it be found out?

2103


Differentiate between ideal and non-ideal voltage sources?

1160


Sir, plz tell me how droop setting is done in parellel operation od DG set ? please give practical example ?

2184


how we findout a ignater is faulty or not?

2165


what is the use of vcb & isolator in substation?

2467


What is servo lock in CNC how they work and if any parameter for them in CNC machine

5410


What is electrical cable termination

2689


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

1894


can u tell me the promotion from oiller to enginer

1993


what is errection pcbs?

1982


can some one clearly explain why -48 volt DC use in telecom site????

1749