Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

what is cold loop? difference between hot and cold loop?

Adani Power,

2304

what is the use of impulse line in AFBC boiler , WHY WE CONNECT IMPULSE LINE TO TRANSMITTER , DRFT GAUGE ETC ????????

Jindal, Reliance,

6 15757

What are the most frequent problem faces with Vortex flow meter?

1 3926

Control valve Flow characteristic. How the equal percentege curve form?

5 11049

what is instrument philosophy

United Automation,

2332

what is the difference between sensor and tranducers?

12 19376

how to calibrate any tansmiter by loop or hart calibrator

2 6328

WHAT IS THE DIFFERENCE B/W PLC and DCS

Bhel,

10 15519

What is a PID?

6 10182

Explain how thw analog to digital converter works with the circuit diagram

2728

what is three element loop

7 20022

Why the industry's standard current standards are from 4mA to 20mA,not from 0mA or any other range?

3 7846

We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.

Sabic,

2382

why pneumatic control signal output is use 0.2 to 1 kg/cm2

Jindal,

3 9866

Why we use mmwc unit for pressure

3 9171


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

How is automatic reference junction compensation carried out in temperature recorders?

1153


Why we are using reverse action in displacer types level transmitters on some Vessels?

2605


List three types Level Switches with their working principles

2188


what is sliding spool valves?

2295


can any one explain in which term we are flow flow is it volumetric r is it mass? and y

1993


State some of balance principle’ advantages?

1232


What is three element in drum level?

1456


How we connect a instrument with ground, Give brief explanation with help of diagram?

2149


draw shematic diagram of c/v positioner(smart type)?

2274


on interface level transmitter model(RTG3302-EMERSON) What is threshold valve how can we select correct threshold value T1,T2,T3,T4 When interface water & hydro carbon

2218


What types of Instrumentation Related Questions can an Interviewer ask in a Telephonic Interview ?

2566


What is the use of temperature compensation?

2075


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1991


How hart protocol can be connected with control valves?

1106


Can anyone send most commonley asked Instrumentation questions and answers in cement industry please?

2038