Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

GIVE BRIEF DESCRIPTION ABOUT "DCS"

2 5662

List three types Level Gauges with their working principles

ABB,

2086

List three types Level Switches with their working principles

2135

List three types Level Transmitters with their working principles

ABB, Bapco Bahrain Petroleum Company,

1 3316

Difference between 2-Valve Manifolds, 3-Valve Manifolds and 5-Valve Manifolds 3 with diagram

Acire Systems,

3111

y v r connecting 250 ohms resistor in series when u cummunicate with BT in bench calibration?

5 8464

diff bw range and span?

3 6289

plz tell me clearly about PID.."when v have to change I value,D value,GAIN??

2178

what is output of FOUNDATION FIELD BUS transmitter

2147

I work on a electronic positioner transmitter 4211 at the field.I connect my multimeter in series to get the current output then I calibrate it to 4ma in 0% of position of the valve and 20ma in 100% position of the valve.My problem is in the field I get the correct output current based on my multimeter but in the dcs they only receive 40% in a output 20ma of this positioner.Then I try to simulate in this analog card and they receive the equivalent percent on the value that I simulated.Is ther any possibility to reset the zero and span of this positioner 4211 fisher.And what other possibility I can do to fixed this.This is my email add ( landicho_randy@yahoo.com )

4 9487

my data card only does run in my mobile so how can change it that it run other mobile & computer and i can stor data in my data card

2271

i have level transmitter -400 to 0 range for steam drum application but i am unable to calibrate if installation of lt below lower tap what will be the effect ? and as per std wht is location of lt ,above lower tapping or below

1 4786

WE ARE HAVING YOKOGAWA CENTUM CS 3000 DCS, 2 FCS AND 4 HIS " When the operation Download to HIS message appears: Equalize start. HIS0163 WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. HIS0163 ---- ERROR = 3 WARNING = 1 ---- Tell me, please, why and how to solve the problem."

Khas Pvt Ltd, Yokogawa,

6 25803

If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?

QAFCO,

2100

If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , then it will reaches again 50%, this type of action occured frequntly.. so what to do for solve this problem. The possible cause is in volume booster or positioner's relay.. positioner is double acting .. and make siemens..sipart.The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?

Gujarat Fluorochemicals Limited (GFL), Shell,

2 12961


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

Why we are using DPT(Differential Pressure Transmitter) in separator instead of level trasmitter?

2293


What is zener diode? What is voltage regulator?

1103


is motorized valve closed when power shutoff?

1734


what is thermo coupler and how it works

6087


Differentiate between ultrasonic flowmeter and radar type flow meter

1217


What is the difference bitween control net scaner and device net scaner

3591


Hi Friends i need Electronics&Instrumentation Engg question papers for BARC written test by coming 20th May 2008 pls post ur use full info to kkumarei@gmail.com. Or for suggestions pls give one missed call to 9962122264

1951


What is the formula of vabration sesore. i mean how to covert mils to volt plz share if any body knows   very argent : my mai is merajalam143545@yahoo.com

2518


Which tank weighing system is better to install (Accuracy point of view) 1) Tank weighing system with 3 load cell or 2) Tank weighing system with 4 Load cell

1311


where cascade loop use ?

1714


you must show the examples application and give at least 4 types of transducer/sensors that can minimize the failure during the manufacturing of the resistors.

3332


Why ac supply load cell is used? Can we use the dc supply load cell?

1070


what happen if i increase height of displacer type LT.accuracy or sensitivity are affected.why?

2483


in which principle pressure tx,level tx ,flow tx,temp tx ,control valve works?

3179


how do we commission inergen system?

1952