Instrumentation Interview Questions
Questions Answers Views Company eMail

GIVE BRIEF DESCRIPTION ABOUT "DCS"

2 4711

List three types Level Gauges with their working principles

ABB,

1639

List three types Level Switches with their working principles

1623

List three types Level Transmitters with their working principles

ABB, Bapco Bahrain Petroleum Company,

1 2536

Difference between 2-Valve Manifolds, 3-Valve Manifolds and 5-Valve Manifolds 3 with diagram

Acire Systems,

2683

y v r connecting 250 ohms resistor in series when u cummunicate with BT in bench calibration?

5 6778

diff bw range and span?

3 5158

plz tell me clearly about PID.."when v have to change I value,D value,GAIN??

1683

what is output of FOUNDATION FIELD BUS transmitter

1694

I work on a electronic positioner transmitter 4211 at the field.I connect my multimeter in series to get the current output then I calibrate it to 4ma in 0% of position of the valve and 20ma in 100% position of the valve.My problem is in the field I get the correct output current based on my multimeter but in the dcs they only receive 40% in a output 20ma of this positioner.Then I try to simulate in this analog card and they receive the equivalent percent on the value that I simulated.Is ther any possibility to reset the zero and span of this positioner 4211 fisher.And what other possibility I can do to fixed this.This is my email add ( landicho_randy@yahoo.com )

4 8008

my data card only does run in my mobile so how can change it that it run other mobile & computer and i can stor data in my data card

1813

i have level transmitter -400 to 0 range for steam drum application but i am unable to calibrate if installation of lt below lower tap what will be the effect ? and as per std wht is location of lt ,above lower tapping or below

1 3794

WE ARE HAVING YOKOGAWA CENTUM CS 3000 DCS, 2 FCS AND 4 HIS " When the operation Download to HIS message appears: Equalize start. HIS0163 WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. HIS0163 ---- ERROR = 3 WARNING = 1 ---- Tell me, please, why and how to solve the problem."

Khas Pvt Ltd, Yokogawa,

6 22745

If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?

QAFCO,

1631

If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , then it will reaches again 50%, this type of action occured frequntly.. so what to do for solve this problem. The possible cause is in volume booster or positioner's relay.. positioner is double acting .. and make siemens..sipart.The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?

Gujarat Fluorochemicals Limited (GFL), Shell,

2 11906


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

the whole paper was based on Transducers..questions like define repeatability, error,accuracy,precision..den there were many q. on the conversion of Pa to mmHg and other units.. also..der wer few Q. on some level sensors(with diagram)

1536


Draw symbols of the following :

1527


why we use cascade control and feed foreword control in 3 element control of boiler drum ?what is feed forward and cascade control system ?

1752


Can anyone convert a 5/2 way or 3/2 way valve into an ISO valve?

479


HOW TO SOLVE PROBLEM WITH ENRAF LEVEL TRANSMITTER 854 ATG THAT PASSWARD DO NOT Exist INTO TRANSMITTER TO ADJUST LEVEL WITH PORTABLE PET 847, WRITTEN WRONG PASSWORD , I AM SURE THAT DEFAULT PASSWARD (W2=ENRAF2) IS THIS TRANSMITTER NEED TO REPLACE SOFTWARE AND HOW?

2967






Name different parts of a pressure gauge. Explain the use of hair spring in the pressure gauge.

664


can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).

1593


What is the difference between uv and ir scanners? and what is the workig principle of both

1940


What is limitation of the ht.of the displacer of a level trol?

1831


we are using centum vp as monitoring with Dell precision work station T3600 but some times PC(s) are restarted automatically . how we can solve this problem? thanks

1756


how pressurize drum calibrated ?

1573


draw the block diagram of a level transmitter ?

1928


How to Calibrate Level Troll in field

764


Why thermo wells are used? What materials are used in thermo wells?

652


what is the advantage of submersible level transmitter compare to ultrasonic level transmitter?

1623