there are two candidates p and q in an election.During the campaign,40% of the voters promised to vote for P ,and rest for Q.however, on the day of election 15% of the voter went back on their promise to vote for P and instead voted for Q. 25% of the voters went back on their promise to vote for Q and instead voted for P.suppose,P lost by two votes,then what was the total no. of voters.
GATE,
1 5353there are two candidates p and q in an election.During the campaign,40% of the voters promised to vote for P ,and rest for Q.however, on the day of election 15% of the voter went back on their promise to vote for P and instead voted for Q. 25% of the voters went back on their promise to vote for Q and instead voted for P.suppose,P lost by two votes,then what was the total no. of voters.
GATE,
4 19856Explain about 4 wire instrument concept & tell about its wiring fron sensor in Field to PLC panel.Explain with an example?
IOCL,
3 13047Explain about relays.. Can we give both AC and DC to the same relay... How it is energising.. Explain its working..
IOCL,
7 14411I am a electronics and instrumentation fresher trying for a job in IT sector. what do need to prepare for the interview?
2 4617In RTU Panel we are having several Analogue & Digital Inputs /Outputs. We are recently facing some problems over Analog inputs , which are not updating properly (But Digital Input are updating normally) Can any one tell me from where the problem is creating , we have checked PLC CPU card, Analog Input card & we reconfigured ,But still the issue is there. Issue : 1. Sometimes Analog values are updating & sometimes not. 2. Analog values are not updating normally , showing some wrong Values 3. Total dead (0 value) Analog values are Level & flow measurement from the field instruments. (But in field the instruments are working normally & Displaying the values normally in local display unit) This problem we are facing in our Water Plant. If any one experienced this same problem or having any ideas related to our issue PLS send your valuable Answers/Replies...
L&T,
6 8705Post New Instrumentation Questions
explain key exchanges in all security modes WPA,WPA2,TLS?
Do you have reference list?
I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?
What are the error values can accepted in flow transmitter calibration?could u give any formula for this?
What is compensation for flow ? Why we use compensation ? What are the factors of different compensation ? We not use then what problems may happen ?
where proximity sensor installed on tank in loading arm application
what is installation and commissioning of (fat & sat) of power plant dcs ? this question keeps in desirable conditions of one company .
What is the advantage of using locally fabricated hook ups over Pre fabricated hook ups in process instrumentation?
What is zero elevation and zero suppression?
What is 3 selection available when configure the burnout protection for controller
Explain an adaptive / self-tuning controller’s major draw card.
I have completed B.E. Instrumentation & control in 2009. i have 3 year industrial job experience in chemical plant.now, I want to join M.E. in external. so, Plese say easiet way and good institute name.
Why are the uses 24vdc in industries
how works encoder in plc
how to calibrate steam control valve in steam turbine