Analytical Chemistry Interview Questions
Questions Answers Views Company eMail

WAHT IS THE ELUTION ORDER IN GAS CHROMATOGRAPHY?

Micro Labs,

3 13303

what is the defferance between the potency and working standard

Arbro Pharmaceuticals, Caplin Point, ECOlogics, Matrix, Orchid, Venus Remedies,

1 5178

what is the principle involved in determination of moisture content?

3 9658

what is difference between assay&purity&potency?

5 31119

why we do the calibration of limit of stry light in hplc & uv

Cipla,

1 3441

what is leading peak in hplc

Cipla,

1 11785

what is difference between drug products and drug substance?

DRL,

5 89405

From peak purity spectrum, where or at which point peak purity angle & purity threshold is checked?

Cipla, MSN Pharma,

1 3489

how you determine moist.of NaOH sol or NaOH flacks

1766

what is concentration of oxygen in U.H.P. grade N2 cylinder

1 4339

water is more polar than acetonitrile.but in reverse phase chromatography peaks elute earlier when we increse Acetonitrile.what is the reason.

Matrix,

10 48862

I got 88.0 % assay for a drug in HPLC analysis for same injection i got 40.0% related substances is it possible? what is the relation between results of assay and purity?

5 10260

hi i am m.sc organic chem and complete analytical lab tech dipolma now job in qc many time ask question you in m.sc organic why job in qc please help me i can not give proper ans please tell me

Arch Pharmalabs, Natco,

3 9746

why use benzophenone & caffene acetone in hplc calibration

1 16589

why use k2cr2o7 , kcl h2so4 in uv calibration

DRL, GVK,

1 9803


Post New Analytical Chemistry Questions

Un-Answered Questions { Analytical Chemistry }

effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?

318


What is the diference between residual solvents and organic volatile matter

1475


before starting analytical method valodation what you checking? and how giving preference to start validation?

331


how require to set assay concentration for standard and sample?

355


which are the sizes of capsules?

393






how you start the solubility study?

333


In IR spectra, generally a molecule vibrates without apply emr or ir light?

1428


How to know the estimated LOQ concentration in ppm

723


in DMF having extra impurities and in api COA also having extra imp than USP or BP product then how require to proceed?

340


What is rs test why we are performing rs test?

1295


what is the origin to prepare standard operating procedure

1776


what is the importance of peak purity in HPLC and how we can calculate through manul(not software)?

3979


how to select short coloum and long coloumn for new molecule

1809


sop of a uv visible spectrophotometer double beam elico model

5342


what is the extinction coefficient for Indomethacin or at 319nm wave length.

3511