Analytical Chemistry Interview Questions
Questions Answers Views Company eMail

IN pH CALIBRATION,CALIBRATION IS DONE FOR pH METER OR ELECTRODE?HOW WILL YOU JUDGE THAT THE METER TO BE CALIBRATED WITH 4,7,9.2 BUFFERS?EXPLAIN TEMPERATURE EFFECTS ON pH.

Aurobindo,

1 10252

AT WHAT CONDITIONS WILL YOU ANALYSE A SAMPLE,WHICH ARE PRESERVED AT OTHER THAN THE AMBIENT CONDITIONS?(ie COLD STORAGE SAMPLES BELOW 20* CENTIGRADE?

1603

What is a base line?

2 10190

what is differance between density and specificgravaty

Neuland,

2 10521

what is defferance between dipolemoment and polarity

Neuland,

1 7383

In standard weight box used for calibration of analytical balance there are two numbers (Qty) of 20mg, 200mg,2.oGM weights. Why?

Orchid,

2 14637

WHAT IS USE OF ION PAIR REAGENTS?

3 8775

How to calculate signal to noise ratio by this formula 2H/h where h from where and how to measure

2 9324

How to choose the which salt is suitable for mobilephase

Cipla, Ranbaxy,

2640

What is quality controle.

6 10147

What is Standard deviation

Cipla,

2 11002

When you get Moisture content by KF higher than by LOD, what does this indicate?

7 15728

what is deference b/w the working standard and reference standard

4 25757

How do we fix the sample concentaryion in hplc method development. what is the basis?Thanks in advance

DRL, Glenmark, Orchid,

4 19245

Suppose we prepared pH buffer solution in lab.and calibrate against NIST solution, and same shall going to used upto 30 days. is it possible to stable pH and apperance ? suggest ?

Orchid,

1 5327


Post New Analytical Chemistry Questions

Un-Answered Questions { Analytical Chemistry }

how a particular wavelength can be different for a particular compund while analysing by uv and by HPLC.

1832


What is the Formula for coreletion coefficient in plhplc calibration

1236


In the isomers,enantiomers give the only physical properties present such that no chemical properties present.

1770


Ph meter can show more than 14 ph reading? Why ph range in between 1 to 14 only?

301


why we use a particular hplc column for a particular compound give reasons?please

2263






We use Potassium Dichromate solution for the calibration of UV-Visible Spectrophotometer in UV region. My question is to calibrate visible region which solution could be used in photometric accuracy

1311


if you have given one product then how you determine the impurity in that?

284


Identify problem faced when mass spectroscopy is used with HPLC system ?

1373


acceptance criteria for lod & loq by standard deviation of response and slope??

2084


function of detecter in hplc ,gc and spectroscopy? function of carrier gas in gc?

2058


how you confirm the assay method?

281


why digestion require in icpms?

301


How to calibration of the uv spectroscopy and its test?

663


why we are using hexane in calibration of number of drop per mL

1163


In performance Check of GC Why Hexadecane Peak is Considered 

2552