Question { 3531 }
This is about the recent problem that we have faced in our
project site.
We have 6/7.5 MVA. 66/11kV three phase star - star power
transformer. The neutral was solidly connected to the
earthing mat. But because of high resistance of earthing
mat (130 ohm on LV and 180 ohm on HV), one day LV side
neutral earthing conductor melted and we had a huge damage.
Can any one plz tell me what might happen when we connect
power transformer neutral to the earthing mat which has
high resistance (>100 ohm ) ?????
Answer
Is This Answer Correct ? | 1 Yes | 0 No |
Question { 3963 }
why we are connecting the alternator to a steam turbine of
higher RPM then the rated RPM of alternator?
For example:( connecting 1500 rpm alternator to 7600 rpm
steam turbine). we can directly connect the same rpm
turbine to alternator know??? is there any special reason ???
Answer
Is This Answer Correct ? | 4 Yes | 1 No |
Question { 2098 }
Why are we not getting shock while touching a metal which
is being welded?
Answer
Is This Answer Correct ? | 0 Yes | 0 No |
Question { 3066 }
What happens if we give the supply to the rotor of induction
motor and make its terminal shorted?
Answer
Is This Answer Correct ? | 1 Yes | 0 No |
Question { 5545 }
all 3 current transformers (C.T) are burnt in a L.T Panel -
what are the possible reasons
Answer
Is This Answer Correct ? | 2 Yes | 1 No |
Question { 3914 }
I have an enquiry of develop solar power plant, 0.69/11kV,
1500kV/750/750kVA, Dy11y11 Transformer. I want to know what
does 1500kV/750/750kVA means? Sorry if this is a noob
question.
Answer
Is This Answer Correct ? | 1 Yes | 1 No |
Question { 2928 }
why we use low kv lightining arrester in line for example 9
kv using in 11kv
Answer
Is This Answer Correct ? | 6 Yes | 0 No |
Question { 2930 }
how df/dt relay operates & how it works?
Answer
Is This Answer Correct ? | 2 Yes | 0 No |
Question { 1760 }
an amazing situation was faced when an alive distribution panel with 415 volts and carrying almost 200Amps has become short and this metal cubical showing 220 volts against neutral and earth. to redress any confusion i checked the panel with help of single 200watts test lamp which also glowing with max.intensity b/w neutral & metal body of DB. amazing situation is that i hold the DB firmly more than once with necked foot means without insulated shoes but not received any electrical shock. whereas our all running gen sets neutral points also proper grounded and this short DB was completely earthed , this is beyond my understanding . any body explain how is it possible . our running gen set neutral also grounded firmly
Answer
Is This Answer Correct ? | 0 Yes | 0 No |
Question { 6584 }
what is the highest voltage for transmitting electrical
power in india
Answer
Is This Answer Correct ? | 20 Yes | 0 No |