How to calculate current carrying capacity of copper conductor _ such as cable size 25sq mm,50 sq mm, 75 sq mm, 100 sq mm
2 4505What is the difference between diesel generator engine with and without turbo charger with the same capacity?
1687a 440v 60hz 03 phase 100kw generator can deliver how much power in kw for 220v 60hz 01 phase load?
1 2372can we use the 110 v primary Tr 240 v secondary step up Transformer as reverse 240 pri 110 sec
3 4335Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir
1939why generation voltages are 6.6kv or 11kv and why not some one give that stander that generation voltages are 5kv or 12kv?
AES,
1 4073Post New Electrical Engineering Questions
Please tell me in DETAIL about the following 3 types of fuses or recommend me a good power system protection book or a website link ? 1.Dropout Fuse 2.Striker Fuse 3.Empulsive fuse (not sure if its impulsive or explosion fuse , sorry)
The power supplied to a 50mH inductor from a 120V, 60Hz source will be
i need project topics along with circuit diagram in the electrical and electronics engg and also some websites regarding projets.
how does the rotating m.m.f is produced in the 3-phase induction motor and how the poles are created in 3-phase induction motor ?
33kv substation lay out details & line to line & line to earth measurements
what is load despatching
What is the use of iron core in a transformer?
Difference between HRG and NGR. Are they both the same thing
help me with the question that might be ask on the interview for technical position
How to calculate pitch, gauge of winding wire, and No. of turns for 30HP, 3 phase, 4 poles 50Hz, 380V induction motors
what is the effect of back reactive power on the generator ?
How to calculate cable size by using load.?? Any formula...
Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir
Phase control and integral control are used for?
what is the purpose of shading ring or shading coil in electrical equipments.