Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

What is center gravity load in substation?

2371

why transformer neutral and CT Secondary neutral is connected to earth?

NCC,

3 4553

What is the main difference between generator and alternator

4 4952

How to calculate current carrying capacity of copper conductor _ such as cable size 25sq mm,50 sq mm, 75 sq mm, 100 sq mm

2 4400

What is the difference between diesel generator engine with and without turbo charger with the same capacity?

1639

what is PDU in transformer?? which company manufacture??

1839

a 440v 60hz 03 phase 100kw generator can deliver how much power in kw for 220v 60hz 01 phase load?

1 2282

can we use the 110 v primary Tr 240 v secondary step up Transformer as reverse 240 pri 110 sec

Hyundai,

3 4179

Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir

1868

how ups works ? various parts of ups and working principle

Serco,

1925

Explain Power factor in simple words

ETO,

1 4091

Describe Non I.S. Earth System and why is it used?

KPJV,

1745

Why lose 1 phase voltage in 33kv to 415v stepdown transformer

1701

why wire sizes are 3/29 or 7/29 and why not wire sizes are 2/29 or 6/29?

OGDCL,

5088

why generation voltages are 6.6kv or 11kv and why not some one give that stander that generation voltages are 5kv or 12kv?

AES,

1 4002


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Explain the iniluencc of short circuit ratio on the pert'orniancc of synchronous machine.

2162


Define phase lag and phase lead?

1082


What is gain margin?

1030


why the active power flow of some line is increased when the active power of out is cut ?

1996


PLS SEND THE RRB CHENNAI MODEL QUESTION PAPER my email id is ganesan98655@rediffmail.com

1981


How much load can be taken for chiller from 1500 kva transformer

1227


What size cable (based on voltage drop) is required to supply a 40 A three phase boiler if the wiring system is 75V single insulated cables installed in non-metallic rigid conduit 56m from the main switchboard? Voltage drop in the consumer's mains is 8V.

1929


what is the difference between unarmoured & Flexible cable? How to identified?

6142


if we look on phasor of the transformer vaoltage is 180 oppsite at primary and the secondary so to improve a power factor is secondary should kept negative to improve it primary side means is -.90 became +.90 at other side

1832


Define closed loop control system.

1045


what reason of line current and phase current in star connection and line current and phase current not equal in delta connection?

2056


how did the testing of protection relays done through current injection

2041


how to generator maintenance (A Check, B check,Etc)

2257


on a three-winding transformer relationship delta-delta-star, on third winding why the relationship is a star? what are the advantages and disadvantages? Thank you and please help

1700


how to measure dc earth leakage current?

3093