What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

CEB,

975

Can i replace Earth leakage relay to the faulty Earth Faulty Relay

1043

How to Calculate KA Rating of Main LT Panel

1182

Control wiring of a dol starter for forward and backward

Basj Industries,

1042

why transformer tank is in rectangular shape what happen when it is in step shape

953

The efficiency of a 100kva transformer is 0.98 at full load as well as half load , for this transformer what is the Copper loss at full load ?

1808

How to calculate Temp from Resister from PT100 equation,

1206

explain which quantities change in the starting and the and the running condition in induction motor

Gulf Spic,

954

what is a composite error in current transformers, why occurs & in which it will occur i.e, either metering ct/ protection ct

1300

Why open circuit test of transformers is conducted at rated voltage??Why not any other voltage??

1123

Why the power factor improvement is so important in industrial loads

1404

How can we convert 11 kv to 440 volt without using transformer ?

Electrical,

989

can we use engine degreaser for electrical motors?

1297

Why auxiliary transformers are not connected in parallel in primary stations?

Adweb,

960

What will happen if i used 11KV earth ht kit to 11 KV / 11 KV cable termination?

990


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero

1811


How we can recongnise the phase displacement of transformer connection between primary & scondary...plzzz explain it with example.........

1938


difference between the applicability of nortons and thevenin theorem

1553


What do you mean by passive circuit elements and why these are called passive?

662


anyone please send transformer parameter design formulas & details of tap changer ? plz i have interview this week its more helpful for me ?

1437






which network topology offers the greatest level of tolerance?

1583


Can we convert off line transformer to on line transformer

1477


what is the correct format to create a resume for interview??

1515


defination of lines

1538


Why insulation level follows this order? transformer < bus bar < circuit breaker & Isolator < transmission line.

1689


what happens if earth of 33kv cable is not connected to earthing pits? please send this query's answer to ngrm.sudha249@gmail.com

1552


If i am running of spindle at 2000rpm ,but How to spindle stop at the second I am resetting the machine in CNC machines

1230


why the voltage and current in a long transmission line are called travelling wave?

1784


How many kinds of E.L.C.B and how to work E.L.C.B

1603


What are all present producing cost of Per KWH of various Fuel?

2121