Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Analytical Chemistry Interview Questions
Questions Answers Views Company eMail

How can we detect a compound in hplc which does not have any chromofore?

1 2465

What is similarity factor?

1206

What is the difference between the working standard and reference standard?

1 2188

WHAT IS THE PARAMETER FOR THE SELECTION OF MOBILE PHASE IN HPLC?

1188

CAN WE DETERMINE THE PEAK PURITY IN GAS CHROMATOGRAPHY ANALYSIS?

1210

How to do spike of aflatoxin in peanut to get maximum recovery

1135

How to fix the sample conc. in Related substances test by HPLC?

1097

What is the limit for single maximum impurity limit as per USP??

1 2001

Why we use potassium dichromate in uv calibration Exact reason behind it??

1259

UV and PDA detector, which have less signal to noise ratio?

1132

Difference between the quantitative analysis and qualitative analysis?

1180

What is related substance by HPLC impurity limits as per USP?

1107

What is a difference between potency and purity?

1221

Why we select scan range from higer wavelength to lower wavelength in uv visible spectroscopy and ftir spectroscopy ? .

911

In the HPLC Calibration done wavelength accuracy done between 200nm-280nm .but not done remaining 300-400nm not done ?

926


Post New Analytical Chemistry Questions

Un-Answered Questions { Analytical Chemistry }

in api coa contains only process impurities and in product coa contains degradation impurities?

701


why sre you used Potassium hydrogen phthalate in standarisation of 1N NaOH and 0.1 N Perchloric Acid?

9798


how you start the solubility study?

827


How to compare XRD graphs against standard and carry polymorpism study of API's by powder XRD method?

3864


effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?

927


what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me

2684


how we can identify the impurity is coming below loq at transfering site?

873


what is procedure of actual procedure for registration of drug?

2012


What is third generation HPLC Columns?

1981


why we are using benzene, anyline in acetic anhdride assay titration method?

2115


in which situation require to take incident in validation?

1727


why salisylic acid not using now days for disdolution calibration?

772


in sampling of raw material which side is pasted sampled labels

1838


We use hicrome 10 cxs column in hplc analysis....pls tell me.. what is the meaning of 10 cxs?

1719


What is gelatinization?

1618