Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

So I'm a first year apprentice and I'm having a tough time with knowing the difference between AI, AO, DI, DO. I'm having a hard time understanding what devices are which and why. Can someone explain this to me?

2 2981

How to calibrate the flow transmitter

1657

i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1522

We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

OPaL,

1724

What is 3 selection available when configure the burnout protection for controller

EI Electrotechnical Institute,

2751

Why trim span ? How?

1683

Any body have know try work calculation ???

1478

What is cut off relay? And why use in PLC and DCS?

1419

Please why do we use 4-20ma in instrumentation engineering

1 2020

If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?

1540

How is work 5/2 sov?

1946

open tank and close tank leavel transmiter about range and calibration

1587

Can we use mov instead of esdv Explain the reason

KOC,

1 2482

What are the questions asked in fresher instrumentation candidates

Polmon,

1528

How we calculate orifice plat size???

1581


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

pls give me presant awerness quistion and answer in my emailid.

2940


can u briefly explain aboutan aryton shunt multirange DC ammeter?

2791


Explain the combusion chamber

2078


my data card only does run in my mobile so how can change it that it run other mobile & computer and i can stor data in my data card

2331


Calibration procedure for Electro magnetic Flow meter

4542


Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?

1947


what is commisioning procedure,2)what is is the main work in commisioning in the field tx to dcs, plz send me detail

2372


basic connection and principle of axial shift sensor n differential sensors in tubine describes n draw......

2421


we want to control pump in let pressure and tank (for exp) our inlet line if water cam and pump will on and when our tank will full pump will off also if our inlet pressure low pump will off even tank not full.this pump i want to uses on our water supply line.

1773


Explain about the leakage class of the control valves

2040


which type of zones used for boiler? & why ?

1917


what is dc moter.

2289


What is zone,loop/fire alarm system?

2749


How to convert milliampares into flow??

1777


Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.

2335