So I'm a first year apprentice and I'm having a tough time with knowing the difference between AI, AO, DI, DO. I'm having a hard time understanding what devices are which and why. Can someone explain this to me?
2 2981i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
1522We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.
OPaL,
1724If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?
1540Post New Instrumentation Questions
pls give me presant awerness quistion and answer in my emailid.
can u briefly explain aboutan aryton shunt multirange DC ammeter?
Explain the combusion chamber
my data card only does run in my mobile so how can change it that it run other mobile & computer and i can stor data in my data card
Calibration procedure for Electro magnetic Flow meter
Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?
what is commisioning procedure,2)what is is the main work in commisioning in the field tx to dcs, plz send me detail
basic connection and principle of axial shift sensor n differential sensors in tubine describes n draw......
we want to control pump in let pressure and tank (for exp) our inlet line if water cam and pump will on and when our tank will full pump will off also if our inlet pressure low pump will off even tank not full.this pump i want to uses on our water supply line.
Explain about the leakage class of the control valves
which type of zones used for boiler? & why ?
what is dc moter.
What is zone,loop/fire alarm system?
How to convert milliampares into flow??
Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.