Need Intergraph softwares like SPI(INTOOLS),sp3d,PV ELITE, SP P&ID. CONTACT : logu.2211@gmail.com (8867825756)
GE,
2258what is the pressure in the tank when its level of liquid is 1.5 meters when its total capacity is 2 meters
2 3748what will be the pressure in tank which has the total level of 2 meters and is filled 1.2 meters ?
4 5143How much Resistance Show by RTD(PT100) when it is installed in process(Consider Process Fluid temp 29 Deg C)?
5 5532What is the formula to convert mv to temperature in k type thermocouple?pls simply elaborate? I got one ans.it is Temp=mv×25°+atmospheric temp,but here what is 25°,i confusef ,so pls????
HPCL,
2 5126Post New Instrumentation Questions
Which language of programing is popular? how can i learn it ?
installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,
Dear Friends, we are planning to design Power distribution and Fiber optic in the same cabinet.Like Front side Fiber optic and Rear side Power distribution.Is it any possibility of problem occurs like interference etc? Your answer is highly appreciate.
There are many type of control cable like pair,core,tried, What are defination each one
How to Calibrate Vibration Probe (Axial, Redial) in field
Basically iam Instruemntation Engineer, but Iam interested in Instruments design engineering, so plz guide, is there any course, training or Softwres to become Instrument design engineer??.
How we connect a instrument with ground, Give brief explanation with help of diagram?
how to calculate orifice sizing? and tell me if pipe size bet 50mm t0 200mm then we can use pipe flange??? and above 250mm pipe size should i use D & D/2 Flange? is it right or wrong?
Which type of diagphram use in costic line,DM water line,natural gas line,oil line?
Define the difference between a stable versus an unstable controlled system and some of the tools you might use to be able to detect when this is happening and assumptions used for control system application design that could contribute to instability
How to convert mmWc(mili meter water colam) to tph(ton per hour)?
If i have 4 Allen Bradely make RS logix 5000 PLC and for viewing that we are using 4 RS view SCADA for 4 different packages. Now, I will want to view two packages on only one SCADA. Then how i will do it?
what is the procedure to callibrate temp controller ,pressure controller,etc. suppose a temp controller showing error 1.5 degree centigrate how can i minimize it.
can anyone tel the syllabus or previous year question paper for BHAVINI(EIE)2014.
what will the sending unit in the fuel gauge utilizes?