For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?
3128In dissolution apparatus how did you calibrate the distance from end of paddle to bottom of the bowl?
1 5099Post New Instrumentation Questions
what is the calibration procedure for magnetic flow meter @ onsite
What happen if we install my pressure transmitter below the elevation of pipe in natural gas service?
hii my name is sujith...i am preparing for HPVL GET 2010... so ,,,pls help me by send any previous questions or material to my site.....(Msujith_12@in.com) thank q
how radio frequency level probes works with its controller ? what is its principle ? pls give me brief explanation?
please tell no. & add. of consultancy who recruit me in power plant as instrumen engg. present i m working in power plant as ass.t instrument engg. thanku mahesh 09226562826
i have steam drum height 1000mm. and i want to placed the transmitter below the tap.how i calculate.
Hi, I am Newely Joined in Construction company instrument engineer? Any one can Plz tell me How can I advanced preparation for Releated Engineering and construction Documents?
if my flow is 20000 m3/h than which range of DPT i have to use????
give eg of how I/P is used in control loops
How a conductivity sensor & analyzer work at boiler, whats the principle & science is beyond this,How conductivity sensor sence & convert signal & move toward analyzer & analyzer show reading in percent? also what is temperature compensate option in conductivity analyzer
sir, i preparing hpcl,ongc,barc,hal exams(instrumentation engg)pls send a placement papers
, Instrument Index, P&ID review, I/O schedule, datasheet, DCS / Analyzers specifications, loop diagrams, hook-up drawings.
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
Where is wet leg is used?
Gas equation