Could anyone please suggest me what is the maximum length of data that can be pass as input in //sysin dd * This was asked in interview. TIA
3 13683I have a job which is a long-running one. Processes millions of records. Due to some run-time problem (not a problem due to the job/data) the job abends.What needs to be done to make the job complete successfully.
TCS,
4 10647Immediate Job opening for mainframe professionals in Keane Bangalore. Please find the below details: Organization: Keane India Location: Bangalore Skill: COBOL, JCL,VSAM,DB2,CICS,IMS,REXX,CLIST Exp: 1 to 4 years only Employment Type: Permenant Employee Note: If you have attended keane interview in past 6 months please ignore this job opening. Please respond to email id keanemfjob@gmail.com OR keanemfjob@yahoo.in with your latest resume and following details, We will contact you within 24 hours: Total IT Exp: Exp in Mainframe: Current CTC: Expected CTC: Notice Period:
3998Hi, Say I have 10 flat files and I want to copy all these 10 flat files to a GDG versions flat files (I have GDG base: FDWS01.TEST.RESTORE) in one shot. Can we do that in one shot using a JCL. May be by using IEBGENER. It's a bit urgent. So anyone's fast rely would be appreciated.. Thanks in advance.. 10 flat files ----------------------------------- FDWS01.SUB.RESTORE1 FDWS01.SUB.RESTORE2 FDWS01.SUB.RESTORE3 ; ; FDWS01.SUB.RESTORE10 TO GDG versions ----------------------- FDWS01.TEST.RESTORE.G0001V00 FDWS01.TEST.RESTORE.G0002V00 FDWS01.TEST.RESTORE.G0003V00 ; ; FDWS01.TEST.RESTORE.G0010V00
2 6232Hi, Say I have 10 flat files and I want to copy all these 10 flat files to a GDG versions flat files (I have GDG base: FDWS01.TEST.RESTORE) in one shot. Can we do that in one shot using a JCL. May be by using IEBGENER. It's a bit urgent. So anyone's fast rely would be appreciated.. Thanks in advance.. 10 flat files ----------------------------------- FDWS01.SUB.RESTORE1 FDWS01.SUB.RESTORE2 FDWS01.SUB.RESTORE3 ; ; FDWS01.SUB.RESTORE10 TO GDG versions ----------------------- FDWS01.TEST.RESTORE.G0001V00 FDWS01.TEST.RESTORE.G0002V00 FDWS01.TEST.RESTORE.G0003V00 ; ; FDWS01.TEST.RESTORE.G0010V00
4 22338in job stmt i coded time=(2,30) and in step 1 i coded time=(1,30) and in step i coded time=(1,30), whch one executes first and what happens if step1 and step2 time executes and wht about the remaining time if step and step2 executes
4 7719i have 10 steps in jcl program but i have to exicute only 2,4,6,8th and 10th ?how it's possible?
IBM,
10 37842Hi, can we call catalog( say myproc } proc n times in jcl if so how please explain Thanks in advance
2 8721do we need to mention the location of catalogued procedure for each it's call in a single job?
1 5324
Explain the function of dd disp parameter?
I have a COBOL program that ACCEPTs some input data. How do you code the JCL statement for this?
When The Define Jcl Is Not Available, How Can You Get Information About A Vsam File's Organisation ?
List in order the hierarchical levels of jcl?
What are the parameter we cannot use in procedure? How many instream we can write in single jcl?
What are some jcl statements that are not allowed in procedures?
what sort card you will use to copy the data from one dataset to another dataset?
how to compare two datasets without using superce because output is limited to 133 bytes
How to remove the spaces at end of each record in the output file Via COBOL program? note: The file has a VB length ----TRY
How to do automated restart when a job abend?
how can a gdg base be created in a jcl. What is the difference between empty and scratch parameter while defining/altering gdg base?
I want to join to input files and write the matching fields on to an output file but i dont want the output file a sorted one
What statement can be used to send data to another mvs jes3 node?
What do you understand by the term “keyword” with respect to jcl and what is the opposite of the term?
We can use PASS with permanent datasets also. THEN Which is the condition in which we may use PASS (instead of KEEP) with permanent data sets, while there is no need to specify UNIT and VOL for them like temporary data sets (in cas we use KEEP for permanent data sets) ?