Electrical Engineering Interview Questions
Questions Answers Views Company eMail

How to calculate KW what is the formula for KW.

Toyota, UU,

18 32248

What is the d/f b/w MCCB & MCB

ABC, LMN,

6 17993

what kvrah y we need to take the readind of that

1559

What type of tranformer generaly at soft wares like capacity 2000 kva 1800 kva etc iam confused it CT or PT OR distribution tranformer

3 4646

What is the use of conservater, bucchos relay, breather in a transformer?

Bosch, Wipro, Zadco,

8 24760

Can we use the 60 HZ transformer/rectifier/Motors/Coils in 50 HZ? if not so, why?

3 6042

why contactor not provided between output of VFD and motor?

Siemens,

6 19680

what is pressure relief valve?where it is used????

Mecon,

4 38280

DIFFERENCE BETWEEN POWER AND CONTROL CABLES

NCC,

9 38013

What is the megger value for ht

Electrical,

16 78427

what is derated current of power cable & what is formule to find derated current?

Thermon,

1 13406

what are cable earthing and bus earthing trucks?when and where they are used?

1 6518

in three pin pluge there three pins one is phase and second is earth third is nutral why nutral high diameter compare with phase and earth

Radiant,

10 16040

What is the diffrence between an ELCB(earth leakage circuit breaker) and RCCB(residual current circuit breaker)?which has higher degree of safety and why?

2 7075

what is the function of breather in a transformer

Areva, Bhel, RKM Powergen, Vijai Electricals,

29 107578


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

what is meant by twilight switches 7 where its applicable ?

1410


how much UPS neutral erath leakage current.

3116


i have attended the interview on 4th June,08 at Kolkata in IOCL, can anybody tell me what is its result

1541


What is super thermal power plant? and how it will differ from normal thermal power plant

1830


A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.

1324






Mention the disadvantages of low power factor? How can it be improved?

667


can u give me a brief idea about power line carrier communication ??

1483


What is the capacity of the Fastners 12mm?

1890


what things to be considered when designing UPS

1299


Refernce currents are to be generated using refernce cueernts how can this be done??

1561


How we can come to know the substation range,without go through any name plate ?

1483


what do w do when the output of generator is fluctuating?

1669


What types of CMOS memories have you designed? What were their size? Speed? Configuration Process technology?

3134


what happen if the parallel generator phase angle shift by 1 degree in manual mode

1556


How we calculat the NGR of 3phase Generator, Our generation voltage 11KV

2872