Analytical Chemistry Interview Questions
Questions Answers Views Company eMail

why plane of polarized light rotated by opticaly active compunds?

Glenmark,

1 3509

why plane of polarized light rotated by opticaly active compunds?

Glenmark,

1 6950

Can any one tell what is RECALL OF PROCEDURES is

Macleods,

1 2774

what is the difference between capillary and glass column in GC

1 7448

differance between L1 and L7 columns

Everest,

5 23590

what is basc principle of the HPLC,IR,UV AND GC? what is difference between diffusion spectra and transmision spectra in IR?

Cadila, Dr Reddys, GICC, Mylan, Sygene, Torrent Pharma, Zydus Cadila,

1 20403

plz tall me that any pharmacopeia and guideline is par meted to use 1.68,4.01,7.00,9.00,12.45 buffer for ph meter calibration

Torrent Pharma,

2 3856

In pharmaceuticals formulation OOS applicable in Raw Material(which is not manufacturing in the company. and purchase by approved vendor)).Why?

Orchid,

1 8007

why we use only six bowls for dissolution of a drug

Cipla, Natco, TelePerformance,

1 20334

On which pharmacopoeia basis we can calibrate instruments like HPLC,GC,UV,DISSO,IR etc...

Cipla, Laurus, Micro Labs,

9 22856

why PH range 0-14 explain

DRL, Reddy Labs, Saint Gobain, Viva,

5 62192

How to make up 100ml of a solution cintaining compound A at 95µg/ml and compound B at30µg/ml for an HPLC reference standard.

3 6575

why we prefer kbr for ftir than kcl?

Aurobindo,

5 12594

How do we quantify crystaline and amarpous forms by using (NMR, XRD)spectroscopic techniques? Which any others instruments are useful for this quantification? explain

Graviti Pharmaceuticals, Vimta Labs,

1964

EXPLAIN THE CALCULATION PART OF AN KF TITRATOR CALIBRATION WITH SUITABLE EXAMPLE

2142


Post New Analytical Chemistry Questions

Un-Answered Questions { Analytical Chemistry }

WHAT IS THE PURPOSE WE USE HCL, CHOPPER, BURNER, MONOCHROMATOR in AAS? PLEASE EXPLAIN BRIEFLY

2112


How to determine the EDTA content by potentiometry titration in Ceftriaxine sodium

1993


We use Potassium Dichromate solution for the calibration of UV-Visible Spectrophotometer in UV region. My question is to calibrate visible region which solution could be used in photometric accuracy

1326


[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?

319


Loss of linearity in tkn analysis, possible reasons?

810






What is the difference between chromatographic purity and related substances?

795


What is the formula for relative diffrence for standard solution in solution stability in validation?

316


What is split ratio in Gc? Splitless? how requirr to select?

331


How do we fix the sample concentaryion in hplc method development. What is the basis?

685


what is mean by ambient temperature?

353


WHY given much noise PDA dector then VWD Dector

1508


If suppose 10 methods of dissolution given in pharmacopoeial for single content product then which method out of 10? or all 10 require to follow?

533


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

1774


process of Diclofenac sodium,IP.

1681


sop of a uv visible spectrophotometer double beam elico model

5363