I HAVE GOT TYPICAL PROBLEM WITH THE TEMP.INDICATION. THE PROBLEM IS THE K-TYPE T/COUPLE OUT PUT IS CONNECTED TO A INDICATOR.THE INDICATION FLUCTUATES SOME TIMES AND SOME TIME IT IS STABLE. WHEN I CHECKED OUT PUT OF T/COUPLE THE MV WILL NOT VARY. WHERE AS INDICATION FLUCTUATES. WHEN I GIVE MV SOURCE TO T/COUPLE EXTENSIONCABLE FROM THE FIELD IT INDICATION IS STABLE. WHEN GIVE MV SORCE TO INDICATOR ITS INDICATION IS STABLE. PLEASE CLARIFY.
5 5800generally transmitter power supply having some range(12v to 35v) but the out put(4-20 mA) must same for given input.If we vary the power supply voltage then output mA also to be change according to V=IR. Is there any voltage regulator in the transmitter ?
1 3220generally transmitter power supply having some range(12v to 35v) but the out put(4-20 mA) must same for given input.If we vary the power supply voltage then output mA also to be change according to V=IR. Is there any voltage regulator in the transmitter ?
2 4185what are the steps to follow force a particular input or out put from ics triplex esd system?
1 2578In thermocouple could we use the lug for termination or not,Thermocouple is any time,I am currently concerned with K type.please let me know if anybody know
4 9502I am manjunath having exp in maintenance of chemical plants,know i want to do a design course INTOOLS,after doing design course can we get jobs in design field.sinve i dont have design exp..
1341Someone Please tell me what are the Pre-Commissioning activities in a Thermal Power Plant for an instrumentaion Engg.
2113Post New Instrumentation Questions
why would you like to join our company
How would you choose differential range?
Calibration procedure for water rotameters
How will you calibrate PID controller? explain with example.
OBJECTIVE TYPE QUESTIONS OF ANALYTICAL INSTRUMENTATION
sir, give me placement papers and interview quistion of birla group company of copper.
how to rectify the poor signal strength in utrasonic digtial flow meter ,model:ge digital xce868i
pls suggest suitable MOC of diaphragm for pressure measurement of UREA grade solution service fluid.
Sir,I am going to sit for IOCL written test exam. recently.Can anyone tell me the name of 'Objective type Question Book on Instrumentation Engineering ' which will help me. Pl. mail to bidyut_71@rediffmail.com / bidyut.saha2008@indiatimes.com / bidyut.saha09@yahoo.in
why is not useing in boiler skin thermocople
What is the use of control cable?
what is the usage of QDV & VOLUME BOOSTER
For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?
whats the abbreviation of IOP? is it instrument of power or input open problem?
how to tune siemens sipart electro pneumatic positioner..plz tel me..