Question { 3645 }
Current Capacity of 55sqmm & 80sqmm conductor
Answer
Is This Answer Correct ? | 1 Yes | 1 No |
Question { 2768 }
how wud i know that whether i have to use unitized package
substation or transformer?
Answer
Is This Answer Correct ? | 0 Yes | 0 No |
Question { 3334 }
High Voltage out door substation-annual maintenance, things
to be considered
Answer
Is This Answer Correct ? | 1 Yes | 0 No |
what happens to a turbo alternator if it get trip and 1 out
of 3 poles of circuit breaker in close condition
Answer
Is This Answer Correct ? | 2 Yes | 0 No |
Question { 2815 }
I have 2 Nos of 2500kVA 33/0.415V cast resin transformers.
How to decide on ampere rating of HT Panel?
Also advise me how many panel RMG i have to consider
whether 4 panel ok?
Answer
Is This Answer Correct ? | 0 Yes | 0 No |
Question { 5381 }
what happen if rotor earth fault in AVR system?
Answer
Is This Answer Correct ? | 2 Yes | 0 No |
in our 6.6kv motor feeder[it is having two sources from
Bus A&B] earth fault relay is acting, we checked CBCT
connection and cable meggerd values found very good still
earth fault acting during first two are three start after
that it will hold. please clarify what was the reason. if
same motor is starting from other Bus-A it will start.
Answer
Is This Answer Correct ? | 0 Yes | 1 No |
Question { 3701 }
I've descovered that when the earth wire in a domestic
electrical installation is not connected back to the board
(ground) a voltage of between 9-24v is is found to be
present in the earth wire.
When connected at the board there is no voltage - is this
normal and why does it happen?
Answer
Is This Answer Correct ? | 0 Yes | 4 No |
Question { Indiabulls, 18133 }
In a Tap changing transformer where is the tap connected ,
is it connected in the primary side or it is connected in
secondary side
Answer
Is This Answer Correct ? | 5 Yes | 0 No |
Why the ceiling fan rotates in clockwise direction and table
fan rotates in anticlockwise direction.
Answer
Is This Answer Correct ? | 8 Yes | 2 No |
Question { 3327 }
We have a 62.5 KVA DG with Leyland engine and kirloskar
slipring alternator. We have earthed the neutral, and another
earthing for the dg body. is it necessary to isolate the dg
foundation with rubber pads?
Answer
Is This Answer Correct ? | 2 Yes | 0 No |
Question { 6704 }
a 650 KVA diesel generator is 1500 rpm, voltage is 415V n full load amps is 805 something,when are applied load more than 400 amps it's voltage is dropping, what is the reasons...?
Answer
Is This Answer Correct ? | 1 Yes | 0 No |